High Accuracy MEMS Pressure Sensor Based on Quartz Crystal Resonator

نویسندگان

  • C. Zhao
  • D. X. Han
  • X. F. Jin
  • S. M. Zhang
  • J. B. Zou
  • M. M. Wang
  • W. B. Li
  • Y. B. Guo
چکیده

Beijing Research Institute of Telemetry, Beijing 100000, China; [email protected] (C.Z.); [email protected] (D.X.H.); [email protected] (X.F.J.); [email protected] (S.M.Z.); [email protected] (J.B.Z.); [email protected] (M.M.W.); [email protected] (W.B.L.); [email protected] (Y.B.G.) * Correspondence: [email protected]; Tel.: +86-10-6819-8271 † Presented at the Eurosensors 2017 Conference, Paris, France, 3–6 September 2017.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MEMS Resonators: Getting the Packaging Right

Microelectromechanical Systems (MEMS) resonators have been investigated for over forty years but have never delivered the high performance and low cost required of commercial oscillators. Packaging technology has been one of the primary limitations. MEMS resonators must be enclosed in very clean environments because even small amounts of surface contamination can significantly change resonator ...

متن کامل

Analysis of Quartz Resonator Array Based on Data Fusion Technology for High Performance Thermal Sensors

In order to improve the accuracy and reliability of temperature measurements, put forward a kind of high precision non-contact temperature measuring system, which is composed of the quartz temperature sensor array and microprocessors. The sensor used by the system is the quartz tuning fork non-contact temperature sensor based on polymer line, and the polymer line that is highly sensitive to tem...

متن کامل

A High Fundamental Frequency Quartz Crystal Biosensor Integrated into an Electro-wetting-on-dielectrics Based Lab-on-a-chip

We demonstrate the operation of an Electro Wetting on Dielectrics (EWOD) hybrid lab-on-a-chip system by utilizing a Quartz Crystal Microbalance (QCM) resonator as mass-sensitive sensor. We have tested the formation of a phosphorlipid monolayer out of an aqueous buffer suspension onto the integrated sensor. The altered mass load resulted in a shift of the resonance frequencies. Subsequently, the...

متن کامل

Design and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array

In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...

متن کامل

Design and Fabrication of a Quartz Crystal Resonator Used in a Thickness-Monitor Unit (TECHNICAL NOTES).

This paper deals with the design and fabrication of a quartz-crystal resonator used in a thickness-monitor unit, measuring film thickness in a film-depositing system. A purpose-grown quartz crystal is cut to form the desired wafer. Two gold electrodes are deposited on both surfaces of the wafer to provide electrical contacts. The resonance frequency of the resonator, at room temperature, and th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017