Repeated Same-Day Versus Single Tomography Measurements of Keratoconic Eyes for Analysis of Disease Progression

نویسندگان

  • Wolf Wonneberger
  • Bertil Sterner
  • Ulrika MacLean
  • Margareta Claesson
  • Madeleine Zetterberg
چکیده

PURPOSE Corneal tomography is used to assess progression of keratoconus and to direct clinical decisions regarding corneal cross-linking. The purpose of this study was to analyze the variability of repeated Scheimpflug-tomography (Pentacam Classic; Oculus, Wetzlar, Germany) measurements of keratoconic eyes in a clinical setting and to assess the validity of such measurements as a clinical decision-making tool. METHODS Eighty keratoconic eyes of 45 patients (age range 16-32 years) were examined at baseline and after follow-up periods of 3 to 6 months using 3 consecutive tomography measurements at each visit. Minimum corneal thickness and anterior sagittal curvature map parameters were studied [simulated keratometry (K) astigmatism (SimKast); maximum simulated K-reading (SimKmax); average SimK (SimKave); maximum K-readings on the 3-mm (Kmax3) and 5-mm (Kmax5) rings; and maximum K-reading (Kmax)]. RESULTS When comparing the first measurements at the first and second visits, respectively, 9% to 20% of eyes were classified as progressive depending on which parameter was chosen. Using the average of 3 consecutive measurements at each visit, 5% to 19% of eyes were classified as progressive. An increase in the SD of 3 consecutive measurements of SimKast (SD_SimKast) at the first visit of 1 diopter makes true progression of keratoconus 3.6 times more likely (odds ratio = 3.6; 95% confidence interval: 0.846-16.027; area under the curve = 0.70). CONCLUSIONS The approach used to analyze progression in keratoconus, that is, single versus repeated measurements, may confer a great impact on the decision to perform corneal cross-linking treatment or not.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Title : the Variability of Corneal and Anterior Segment Parameters

30 Purpose: To analyse, describe and test diverse corneal and anterior segment parameters 31 in normal and keratoconic eyes to better understand the geometry of the keratoconic 32 cornea. 33 34 Method: 44 eyes from 44 keratoconic patients and 44 eyes from 44 healthy patients 35 were included in the study. The Pentacam System was used for the analysis of the 36 anterior segment parameters. New a...

متن کامل

Higher incidence of steroid-induced ocular hypertension in keratoconus

BACKGROUND To compare intraocular pressure (IOP) changes following topical dexamethasone administration for 1 month in keratoconic versus normal eyes. METHODS This is a retrospective, single-center, non-randomized case series evaluation of 350 eyes. Two groups were formed: normal/control Group A (nA =73), eyes that underwent excimer laser photorefractive keratectomy; and keratoconic (KCN) Gro...

متن کامل

Use of the structure-function relationship in detecting glaucoma progression in early glaucoma

BACKGROUND To evaluate the use of optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness and visual field (VF) measurements in detecting disease progression in patients with early glaucoma. METHODS Over a 3-year period, this study examined 60 eyes of 39 glaucoma patients whose total deviation in the superior or inferior hemifield was more than -6 dB. All eyes underwent ...

متن کامل

ORA waveform-derived biomechanical parameters to distinguish normal from keratoconic eyes.

PURPOSE To evaluate the ability of the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) to distinguish between normal and keratoconic eyes, by comparing pressure and waveform signal-derived parameters. METHODS This retrospective comparative case series study included 112 patients with normal corneas and 41 patients with bilateral keratoconic eyes. One eye from each...

متن کامل

Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes

Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2018