Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions

نویسندگان

  • Eivind Aadland
  • Einar Ylvisåker
  • Guillermo López Lluch
چکیده

BACKGROUND Reliability of the Actigraph GT3X+ accelerometer has not been determined under normal wear time criteria in a large sample of subjects and accelerometer units. The aim of this study was to assess contralateral hip difference and inter-instrument reliability of the Actigraph GT3X+ monitor in adults under long-term free-living conditions. METHODS Eighty-seven adult subjects (28 men; mean (standard deviation) age 31.3 (12.2) years; body mass index 23.7 (3.1) kg/m2) concurrently wore two GT3X+ accelerometers (174 units in total) attached to contralateral hips for 21 days. Reliability was assessed using Bland-Altman plots, mixed model regression analyses and absolute measures of agreement for different lengths of data accumulation (single-day-, 7-day- and 21-day periods). RESULTS There were no significant differences between contralateral hips (effect size ≤0.042; p ≥.213). Inter-instrument reliability increased with increased length of data-accumulation. For a 7-day measurement period (n = 232 weeks), limits of agreement were ±68 cpm (vertical axis) and ±81.3 cpm (vector magnitude) for overall physical activity (PA) level, ±51 min for sedentary time, ±18.2 min for light PA, ±6.3 min for moderate PA, ±3.5 min for vigorous PA, and ±6.7 min for moderate-to-vigorous PA. CONCLUSIONS The Actigraph GT3X+ accelerometer is a reliable tool for measuring PA in adults under free-living conditions using normal data-reduction criteria. Contralateral hip differences are very small. We suggest accelerometers be attached to the right hip and data to be accumulated over several days of measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three generations of ActiGraph activity monitors under free-living conditions: do they provide comparable assessments of overall physical activity in 9-year old children?

BACKGROUND A recent review concludes that the agreement of data across ActiGraph accelerometer models for children and youth still is uncertain. The aim of this study was to evaluate the agreement of three generations of ActiGraph accelerometers in children in a free-living condition. METHODS Sixteen 9-year-olds wore the ActiGraph AM7164, GT1M and GT3X+ simultaneously for three consecutive da...

متن کامل

Accuracy of StepWatch™ and ActiGraph Accelerometers for Measuring Steps Taken among Persons with Multiple Sclerosis

INTRODUCTION There has been increased interest in the objective monitoring of free-living walking behavior using accelerometers in clinical research involving persons with multiple sclerosis (MS). The current investigation examined and compared the accuracy of the StepWatch activity monitor and ActiGraph model GT3X+ accelerometer for capturing steps taken during various speeds of prolonged, ove...

متن کامل

Validity and Reliability of Fitbit Flex for Step Count, Moderate to Vigorous Physical Activity and Activity Energy Expenditure

OBJECTIVES To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. METHODS Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+...

متن کامل

Actigraph GT3X: validation and determination of physical activity intensity cut points.

The aims of this study were: to compare energy expenditure (EE) estimated from the existing GT3X accelerometer equations and EE measured with indirect calorimetry; to define new equations for EE estimation with the GT3X in youth, adults and older people; and to define GT3X vector magnitude (VM) cut points allowing to classify PA intensity in the aforementioned age-groups. The study comprised 31...

متن کامل

The Fitbit One Physical Activity Tracker in Men With Prostate Cancer: Validation Study

BACKGROUND Physical activity after cancer diagnosis improves quality of life and may lengthen survival. However, objective data in cancer survivors are limited and no physical activity tracker has been validated for use in this population. OBJECTIVE The aim of this study was to validate the Fitbit One's measures of physical activity over 7 days in free-living men with localized prostate cance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015