A cable-stayed bridge recently constructed by the Ohio Department of Transportation incorporates measures put forth by a Federal Highway Administration study to mitigate stay motion. In following recent trends, the stays at this bridge are built without the use of grout for the purposes of inspection and, if necessary, replacement. Several experiments were performed to determine the viability of using traditional vibration techniques, which assume an integral sheath, to estimate cable tension with this new configuration.
منابع مشابه
Development of a Low-cost Automated Tension Estimation System for Cable-stayed Bridges
Cable tension force is one of the most important structural parameters to monitor in cable-stayed bridges. For example, cable tension needs to be monitored during construction and maintenance to ensure the bridge is not overloaded. To economically monitor tension forces, this study proposes the use of an automated wireless tension force estimation system (WFTES) developed solely for cable force...
متن کاملDevelopment of an Automated Wireless Tension Force Estimation System for Cable-stayed Bridges
Cable-supported bridges rely on the use of steel cables to support the bridge deck and load on it. Cable tension forces are monitored during construction to assist the alignment of cables and to ensure no cables are overloaded. Given that the cables are critical load carrying elements, it is prudent to routinely monitor the levels of cable tensions during operation. With current measurement met...
متن کاملDESIGN OPTIMIZATION OF CABLE-STAYED BRIDGES USING MOMENTUM SEARCH ALGORITHM
Design optimization of cable-stayed bridges is a challenging optimization problem because a large number of variables is usually involved in the optimization process. For these structures the design variables are cross-sectional areas of the cables. In this study, an efficient metaheuristic algorithm namely, momentum search algorithm (MSA) is used to optimize the design of cable-stayed bridges....
متن کاملCalibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring
The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors remain challenging tasks. In this paper, we use a case study, Adige Bridge, in order to present a ...