Diffusion-weighted imaging of the parotid gland: Influence of the choice of b-values on the apparent diffusion coefficient value.

نویسندگان

  • Harriet C Thoeny
  • Frederik De Keyzer
  • Chris Boesch
  • Robert Hermans
چکیده

PURPOSE To determine how the ADC value of parotid glands is influenced by the choice of b-values. MATERIALS AND METHODS In eight healthy volunteers, diffusion-weighted echo-planar imaging (DW-EPI) was performed on a 1.5 T system, with b-values (in seconds/mm2) of 0, 50, 100, 150, 200, 250, 300, 500, 750, and 1000. ADC values were calculated by two alternative methods (exponential vs. logarithmic fit) from five different sets of b-values: (A) all b-values; (B) b=0, 50, and 100; (C) b=0 and 750; (D) b=0, 500, and 1000; and (E) b=500, 750, and 1000. RESULTS The mean ADC values for the different settings were (in 10(-3) mm2/second, exponential fit): (A) 0.732+/-0.019, (B) 2.074+/-0.084, (C) 0.947+/-0.020, (D) 0.890+/-0.023, and (E) 0.581+/-0.021. ADC values were significantly (P <0.001) different for all pairwise comparisons of settings (A-E) of b-values, except for A vs. D (P=0.172) and C vs. D (P=0.380). The ADC(B) was significantly higher than ADC(C) or ADC(D), which was significantly higher than ADC(E). ADC values from exponential vs. logarithmic fit (P=0.542), as well as left vs. right parotid gland (P=0.962), were indistinguishable. CONCLUSION The ADC values calculated from low b-value settings were significantly higher than those calculated from high b-value settings. These results suggest that not only true diffusion but also perfusion and saliva flow may contribute to the ADC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer

Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Diffusion weighted magnetic resonance imaging in the diagnosis of parotid masses. Preliminary results

OBJECTIVE To demonstrate the diagnostic potentials of MRI, diffusion weighted imaging (DWI), and apparent diffusion coefficient (ADC) mapping in the detection of parotid masses correlated to the histopathological results. Methods: Study design was retrospective. Fifteen patients with parotid gland masses were included as the study group and contralateral normal parotis glands of same patients w...

متن کامل

Carcinoma ex pleomorphic adenoma of the parotid gland: radiologic-pathologic correlation with MR imaging including diffusion-weighted imaging.

We present 4 cases of carcinoma ex pleomorphic adenoma of the parotid gland. In 3 of the 4 cases, diffusion-weighted and apparent diffusion coefficient (ADC) mapping images clearly revealed carcinoma as a hypercellular area with low ADC values and pleomorphic adenoma as a hypocellular area with high ADC values. Diffusion-weighted images demonstrated well complex tissue components in carcinoma e...

متن کامل

Evaluation of Diffusion Anisotropy and Diffusion Shape in Grading of Glial Tumors

Background: The most common primary tumors of brain are gliomas. Grading of tumor is vital for designing proper treatment plans. The gold standard choice to determine the grade of glial tumor is biopsy which is an invasive method.Objective: In this study, we try to investigate the role of fractional anisotropy (diffusion anisotropy) and linear anisotropy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2004