The Potential Utility of Iodinated Contrast Media (ICM) Skin Testing in Patients with ICM Hypersensitivity
نویسندگان
چکیده
Both immediate and delayed hypersensitivity reactions to iodinated contrast media (ICM) are relatively common. However, there are few data to determine the clinical utility of immunologic evaluation of ICM. To evaluate the utility of ICM skin testing in patients with ICM hypersensitivity, 23 patients (17 immediate and 6 delayed reactions) were enrolled from 3 university hospitals in Korea. With 6 commonly used ICM including iopromide, iohexol, ioversol, iomeprol, iopamidol and iodixanol, skin prick (SPT), intradermal (IDT) and patch tests were performed. Of 10 patients with anaphylaxis, 3 (30.0%) and 6 (60.0%) were positive respectively on SPTs and IDTs with the culprit ICM. Three of 6 patients with urticaria showed positive IDTs. In total, 11 (64.7%) had positive on either SPT or IDT. Three of 6 patients with delayed rashes had positive response to patch test and/or delayed IDT. Among 5 patients (3 anaphylaxis, 1 urticaria and 1 delayed rash) taken subsequent radiological examinations, 3 patients administered safe alternatives according to the results of skin testing had no adverse reaction. However, anaphylaxis developed in the other 2 patients administered the culprit ICM again. With 64.7% (11/17) and 50% (3/6) of the sensitivities of corresponding allergic skin tests with culprit ICM for immediate and delayed hypersensitivity reactions, the present study suggests that skin tests is useful for the diagnosis of ICM hypersensitivity and for selecting safe ICM and preventing a recurrence of anaphylaxis caused by the same ICM.
منابع مشابه
Proposal of a skin tests based approach for the prevention of recurrent hypersensitivity reactions to iodinated contrast media.
The purpose of the present work is to evaluate the efficacy of an approach that combines clinical history, skin tests results, and premedication, in preventing recurrent hypersensitivity reactions to iodinated contrast media (ICM). Skin Prick tests, Intradermal tests, and Patch tests were performed in 36 patients with a previous reaction to ICM. All patients underwent a second contrast enhanced...
متن کاملAllergic Immediate Hypersensitivity to Iodinated Contrast Media
Background: Immediate hypersensitivity reactions (IHR) to iodinated contrast media (ICM) have traditionally been considered nonallergic; however, the increasingly frequent reporting of positive skin test and basophil activation test results suggests a specifi c allergic mechanism in some patients. Skin tests have been proposed as a useful tool for diagnosis, although their sensitivity and predi...
متن کاملExamination of patients suspected as having hypersensitivity to iodinated contrast media with leukocyte migration test.
In vivo tests may be used for the diagnosis of allergy to iodinated contrast media (ICM); however, the tests do not provide definitive diagnosis and are associated with risks for patients. Diagnoses based on in vitro tests are limited, and there are almost no relevant studies. Herein, the authors examined involvement of allergic reaction from a multilateral standpoint in 39 patients suspected o...
متن کاملClinical Practice Guidelines for Diagnosis and Management of Hypersensitivity Reactions to Contrast Media.
The objective of these guidelines is to ensure efficient and effective clinical practice. The panel of experts who produced this consensus document developed a research protocol based on a review of the literature. The prevalence of allergic reactions to iodinated contrast media (ICM) is estimated to be 1:170 000, that is, 0.05%-0.1% of patients undergoing radiologic studies with ICM (more than...
متن کاملCombined Effect of Iodine Contrast Media, Cisplatin and External Beam Radiotherapy on Anaplastic Thyroid Cancer Cells
Introduction: The current study investigated the combination of high Z atoms (iodine-, platinium-based drugs) with using low energy irradiation (120kvp) in Anaplastic Thyroid cancer cells.Materials and Methods: For this purpose, eight groups were designed: control (CNT), different concentrations of Iodine contrast media (ICM), irradiation with various doses, Cis-platin (CDDP) with different c...
متن کامل