Evaluation of 126 Consecutive Stereotactic Procedures: Brain Biopsy, Diagnostic Yield, Accuracy, Non-Diagnostic Results, Complications and Follow-up.
نویسندگان
چکیده
AIM A retrospective analysis of 126 consecutive computed tomography (CT)-guided, frame-based stereotactic procedures in 121 patients is presented to evaluate the diagnostic yield, accuracy, complications, management of non-diagnostic cases and followup. MATERIAL AND METHODS The medical records of the identified patients were investigated retrospectively. Age, sex, surgical procedures, histopathological diagnosis, diagnostic yield, accuracy, complications, management of non-diagnostic cases and follow-up were analyzed in 121 consecutive patients. Stereotactic procedures were performed by the author by using Leksell's stereotactic system, and stereotactic biopsies were conducted under local anesthesia except for those patients who were not able to tolerate this treatment. These patients had control CT scans two hours after the operation. RESULTS Patient age ranged from 2 to 82 years (mean 48 years). Stereotactic biopsy was performed in 112 patients. Cyst and abscess aspiration, intracystic catheter replacement and tumor resection with stereotactic craniotomy were among the other procedures. The diagnostic yield was 93%, and the histological accuracy was 63% with no mortality. Craniotomy and hematoma evacuation were required in two cases. The patients were followed up from one month to 17 years. CONCLUSION Frame-based stereotactic biopsy is a safe and efficacious method with acceptable complications. Experience is important, but not sufficient for preventing complications and performing procedures accurately. Necrosis and gliosis are the most common non-diagnostic findings. Empirical treatment with presumptive diagnoses based on clinical and radiological findings and close clinical follow-up may not affect patients adversely. The follow-up of patients through examination and imaging is important to allow the revision of treatment when necessary.
منابع مشابه
Evaluation of 126 Consecutive Stereotactic Procedures : Brain Biopsy , Diagnostic Yield , Accuracy , Non - Diagnostic
adequate therapy (34). Stereotactic surgery started with the Horsley-Clarke apparatus in 1908 (14). After the introduction of stereotactic surgery in human patients by Spiegel and Wycis in 1947, this approach has been used safely and effectively to obtain tissue diagnosis for intracranial lesions. There are many papers establishing the issues related to the safety, accuracy and diagnostic yield...
متن کاملDiagnostic yield of stereotactic brain biopsy.
OBJECTIVE To evaluate the diagnostic yield, accuracy, and safety of frame-based stereotactic brain biopsy procedures. METHODS A retrospective study of all pathologically diagnosed intracranial lesions, using frame-based stereotactic guided brain biopsy procedures performed at King Faisal Specialist Hospital and Research Centre (KFSH&RC), Riyadh, Kingdom of Saudi Arabia between 1993 and 2005 w...
متن کاملFrameless Stereotactic Biopsy of Intracranial Lesions: Evaluation of Efficacy and Complications
Objective: Frameless stereotactic biopsy has been shown in multiple studies to be a safe and effective procedure for the diagnosis of brain lesion. In this study the authors will evaluate the safety of the procedure and associated complications including neurological deficits in our set up of developing countries. Methods: Forty two patients with different brain lesions were biopsied using fram...
متن کاملComparative analysis of diagnostic accuracy of different brain biopsy procedures.
BACKGROUND Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. AIMS The present study was carr...
متن کاملThe accuracy and diagnostic yield of computerized tomography guided stereotactic biopsy in brain lesions.
OBJECTIVES Radiological imaging techniques provide early detection of neurological diseases but they do not always provide an adequate and reliable diagnosis. With the help of stereotactic biopsy techniques, it is possible to access brain lesions safely and with high precision. We described the surgical method used in our clinic and discussed our results with the help of the current literature....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Turkish neurosurgery
دوره 26 6 شماره
صفحات -
تاریخ انتشار 2016