Biomechanical evaluation of monosegmental pedicle instrumentation in a calf spine model and the role of fractured vertebrae in screw stability

نویسندگان

  • Fuxin Wei
  • Zhiyu Zhou
  • Le Wang
  • Shaoyu Liu
  • Rui Zhong
  • Xizhe Liu
  • Shangbin Cui
  • Ximin Pan
  • Manman Gao
  • Yajing Zhao
چکیده

BACKGROUND Monsegmental pedicle instrumentation (MSPI) has been used to treat thoracolumbar fractures. However, there are few reports about the biomechanical characteristics of MSPI compared with traditional short-segment pedicle instrumentation (SSPI) in management of unstable thoracolumbar fractures, and the influence of vertebral fracture on screw stability is still unclear. METHODS This study was to compare the immediate stability between MSPI and SSPI in management of unstable L1 fracture, and to evaluate the role of fractured vertebrae in screw stability. Two studies were performed: in the first study, sixteen fresh calf spines (T11-L3) were divided into two groups, in which unstable fractures at L1 were produced and then instrumented with MSPI or SSPI respectively. The range of motion (ROM) and lax zone (LZ) of specimens were evaluated with pure moment of 6 Nm loaded. The second study measured and compared the pullout strength of screws inserted in to 16 intact and fractured vertebrae of calf spines (L1-3) respectively. The correlation of pullout strength with load sharing classification (LSC) of fractured vertebrae was analyzed. RESULTS No significant difference in the ROM and LZ of the destabilized segments after fixation between MSPI and SSPI, except in axial rotation of ROM (P < 0.05). After fatigue cyclic loading, the MSPI showed a significant increase of ROM during lateral bending and axial rotation (P < 0.05); however, there were no significant differences in the LZ during all loading models between groups (P > 0.05). The mean pullout strength of pedicle screws in fractured vertebrae decreased by 13.7%, compared with that of intact vertebrae (P > 0.05), and had a low correlation with LSC of the fractured vertebrae (r = 0.293, P > 0.05). CONCLUSIONS MSPI can provide effective immediate stability for management of unstable thoracolumbar fractures; however, it has less fatigue resistance during lateral bending and axial rotation compared with SSPI. LSC score of fractured vertebrae is not a major influence on the pullout strength of screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pedicle screw instrumentation of thoracolumbar burst fractures: Biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture

BACKGROUND Posterior fixation alone may not be adequate to achieve and maintain burst fracture reduction. Adding screws in the fractured body may improve construct stiffness. This in vitro study evaluates the biomechanical effect of inserting pedicle screws in the fractured body compared with conventional short- and long-segment posterior fixation. METHODS Stable and unstable L2 burst fractur...

متن کامل

Biomechanical Evaluation of a Novel Posterior Integrated Clamp That Attaches to an Existing Posterior Instrumentation for Use in Thoracolumbar Revision

STUDY DESIGN An in vitro biomechanical study. PURPOSE To evaluate the biomechanics of a novel posterior integrated clamp (IC) that extends on an already implanted construct in comparison to single long continuous bilateral pedicle screw (BPS) and rod stabilization system. OVERVIEW OF LITERATURE Revision surgery in the thoracolumbar spine often necessitates further instrumentation following ...

متن کامل

Transpedicular bone grafting and pedicle screw fixation in injured vertebrae using a paraspinal approach for thoracolumbar fractures: a retrospective study

BACKGROUND Complications in posterior pedicle screw fixation using a conventional posterior approach for thoracolumbar fractures include vertebral height loss, kyphosis relapse and breakage, or loosening of instrumentation. The purpose of this study was to evaluate the clinical effects of transpedicular bone grafting and pedicle screw fixation in injured vertebrae using a paraspinal approach fo...

متن کامل

Comparison of Supplementary Posterior Fixations for Two-Level ALIF with Stand-Alone Cages

INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...

متن کامل

Cervical Pedicle Screw Fixation: Anatomic Feasibility of Pedicle Morphology and Radiologic Evaluation of the Anatomical Measurements

STUDY DESIGN All parameters were measured manually and with a computed tomography (CT) scanner. For the manual measurements, a Vernier scale instrument was used. PURPOSE This study evaluates quantitatively pedicles of middle and lower cervical spine (C3 to C7) and to evaluate the possibilities of using these structures as anchors in posterior cervical fusion. OVERVIEW OF LITERATURE Pedicle ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016