SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including Resensitization.

نویسندگان

  • W Luo
  • P Aryal
  • M Randall
چکیده

PURPOSE To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS Because of lack of sufficient clinical data, the prescribed dose with new isotopes is usually calculated based on BED compared with other isotopes that have already been used in clinical practice. The current widely used formulism of BED calculation for permanent implant which was given by Dale includes cell repair and repopulation but not resensitization. Resensitization can be included in the extended LQ equation (LQR) proposed by Brenner. Applying Dales formulism to Brenners LQR, we obtained a new BED calculation formula that accounts for resensitization. We used this new formulism to calculate the BED that corresponds to the prescribed dose for cervix (with Au-198) and prostate (with I-125) permanent implant. Then, we obtained the prescribed dose with Cs-131 which has the same BED as Au-198 or I-125. RESULTS The new formulism was used for prostate and cervix cancer permanent implant. The prescribed dose with Cs-131 for cervix was 40 Gy (42 Gy without resensitization) and 66 Gy (69 Gy without resensitization) which were equivalent to 35 Gy and 60 Gy with Au-198, respectively. For prostate implant, the prescribed dose with Cs-131 that corresponded to 144 Gy with I-125 was 135 Gy (124 Gy without resensitization). CONCLUSION Resensitization led to significant dose correction for permanent implant. The calculation of BED and dose was dependent on dose itself and thus should be patient-specific. Since this calculation relied on many biological parameters, and may not be accurate if the parameters are not accurate. Also, the dose prescription should be adjusted based on clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo calculated doses to treatment volumes and organs at risk for permanent implant lung brachytherapy.

Iodine-125 ((125)I) and Caesium-131 ((131)Cs) brachytherapy have been used with sublobar resection to treat stage I non-small cell lung cancer and other radionuclides, (169)Yb and (103)Pd, are considered for these treatments. This work investigates the dosimetry of permanent implant lung brachytherapy for a range of source energies and various implant sites in the lung. Monte Carlo calculated d...

متن کامل

Updating the Planar Patterson-Parker Table for Ir-192 and Cs-137 Brachytherapy Sources Using the Most Recent TG-43U1 Recommended Dosimetric Parameters

Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determined in air and were utilized for dose calculations around implants with Ra-equivalent radionuclides such as 137Cs and 192Ir. Therefore, the differences of the tissue attenuation ...

متن کامل

Edema‐induced changes in tumor cell surviving fraction and tumor control probability in  131Cs permanent prostate brachytherapy implant patients

The study is designed to investigate the effect of edema on the delivered dose, tumor cell surviving fraction (SF), and tumor control probability (TCP) in the patients of prostate cancer who underwent (131)Cs permanent seed implantation. The dose reduction, the SF, and the TCP for edematous prostate implants were calculated for 31 patients who underwent real-time (131)Cs permanent seed implanta...

متن کامل

Resection Cavity Contraction Effects in the Use of Radioactive Sources (1-25 versus Cs-131) for Intra-Operative Brain Implants

Background and Objectives Intra-parenchymal brain surgical resection cavities usually contract in volume following low dose rate (LDR) brachytherapy implants. In this study, we systematically modeled and assessed dose variability resulting from such changes for I-125 versus Cs-131 radioactive sources. Methods Resection cavity contraction was modeled based on 95 consecutive patient cases, using ...

متن کامل

A Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012