Factors that influence microbial contamination of fluids associated with hemodialysis machines.

نویسندگان

  • M S Favero
  • L A Carson
  • W W Bond
  • N J Petersen
چکیده

Studies were conducted on the microbiological quality of fluids associated with different types of dialysis systems located in six dialysis centers and 14 homes. Included were (i) single-pass systems employing either parallel flow (Kiil or Gambro) or capillary cartridge dialyzers and (ii) recirculating single-pass and batch recirculating systems using coil dialyzers. Microbiological assays were performed on the water used to prepare dialysis fluid, the concentrated dialysate, and either pre- and postdialyzer dialysate (single-pass systems) or the dialysate contained in storage reservoirs and recirculating cannisters (recirculating systems). The levels of microbial contamination consisting of gram-negative bacteria were directly related to the type of dialysis system, method of water treatment, distribution system, and in some instances, the type of dialyzer. Recirculating single-pass and batch recirculating systems consistently contained significantly higher levels of contamination than single-pass systems. These results were directly related to the design of recirculating systems which permits carbon- and nitrogen-containing waste products dialyzed from the patient to accumulate, be used as nutrients by microorganisms, and subsequently allow for 2- to 4-log increases in contamination levels during a dialysis treatment. In contrast, levels of contamination in single-pass machines were related more to the quality of the water used to prepare dialysis fluid and the adequacy of cleaning and disinfection procedures than to the design of the system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin.

Pyrogenic reactions (PR) are a well-recognized complication of hemodialysis and have been associated with dialyzer reuse, high-flux dialysis, and bicarbonate dialysate. However, the roles of bacteria and endotoxin in dialysate for producing PR are not well defined. To determine the effect of removing most bacteria and endotoxin from the dialysate on the incidence of PR, a cohort of chronic hemo...

متن کامل

[The quality of dialysis water].

INTRODUCTION Every week, haemodialysis patients are exposed to approximately 400 l of water used for the production of dialysis fluids which, albeit with the interposition of a semi-permeable artificial membrane, come into direct contact with the bloodstream. It is therefore clearly important to know and monitor the chemical and microbiological purity of dialysis water. METHODS In this review...

متن کامل

Assessment of the Microbiological Quality of Caspian Seawater and the Role of Physicochemical Factors on Microbial Load

Introduction: Analyzing the health risk associated with the microbial contamination of seawater is necessary to ensure that there is not any threat to human or environment. The aim of this study was to evaluate the microbiological quality of Caspian sea water using indicator bacteria. Some Physicochemical parameters were studied to assed their association with the contamination level of Caspian...

متن کامل

Ralstonia pickettii bacteremia in hemodialysis patients: a report of two cases

Ralstonia pickettii is a low-virulence gram-negative bacillus that may be associated with infections related to health care and may cause bacteremia. Ralstonia pickettii bacteremia is uncommon but is related to the contamination of medical products, mainly in immunodepressed patients. We present two cases of patients on chronic hemodialysis with Ralstonia pickettii bacteremia linked to contamin...

متن کامل

Analyzing the Quality of Dialysis Machines Input Water in Hospitals of Kashan City, in 2019

Introduction: According to high volumes of water used in hemodialysis, quality of water entering the dialysis machine is very important. The current study aims to analyze microbial and chemical quality of water used for hemodialysis in hospitals of Kashan city in 2019. Materials and Methods: This descriptive cross-sectional study was performed on 54 water samples used in dialysis machines in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 1974