Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform
نویسندگان
چکیده
BACKGROUND Over the past two decades, high false alarm (FA) rates have remained an important yet unresolved concern in the Intensive Care Unit (ICU). High FA rates lead to desensitization of the attending staff to such warnings, with associated slowing in response times and detrimental decreases in the quality of care for the patient. False arrhythmia alarms are commonly due to single channel ECG artifacts and low voltage signals, and therefore it is likely that the FA rates may be reduced if information from other independent signals is used to form a more robust hypothesis of the alarm's etiology. METHODS A large multi-parameter ICU database (PhysioNet's MIMIC II database) was used to investigate the frequency of five categories of false critical ("red" or "life-threatening") ECG arrhythmia alarms produced by a commercial ICU monitoring system, namely: asystole, extreme bradycardia, extreme tachycardia, ventricular tachycardia and ventricular fibrillation/tachycardia. Non-critical ("yellow") arrhythmia alarms were not considered in this study. Multiple expert reviews of 5386 critical ECG arrhythmia alarms from a total of 447 adult patient records in the MIMIC II database were made using the associated 41,301 h of simultaneous ECG and arterial blood pressure (ABP) waveforms. An algorithm to suppress false critical ECG arrhythmia alarms using morphological and timing information derived from the ABP signal was then tested. RESULTS An average of 42.7% of the critical ECG arrhythmia alarms were found to be false, with each of the five alarm categories having FA rates between 23.1% and 90.7%. The FA suppression algorithm was able to suppress 59.7% of the false alarms, with FA reduction rates as high as 93.5% for asystole and 81.0% for extreme bradycardia. FA reduction rates were lowest for extreme tachycardia (63.7%) and ventricular-related alarms (58.2% for ventricular fibrillation/tachycardia and 33.0% for ventricular tachycardia). True alarm (TA) reduction rates were all 0%, except for ventricular tachycardia alarms (9.4%). CONCLUSIONS The FA suppression algorithm reduced the incidence of false critical ECG arrhythmia alarms from 42.7% to 17.2%, where simultaneous ECG and ABP data were available. The present algorithm demonstrated the potential of data fusion to reduce false ECG arrhythmia alarms in a clinical setting, but the non-zero TA reduction rate for ventricular tachycardia indicates the need for further refinement of the suppression strategy. To avoid suppressing any true alarms, the algorithm could be implemented for all alarms except ventricular tachycardia. Under these conditions the FA rate would be reduced from 42.7% to 22.7%. This implementation of the algorithm should be considered for prospective clinical evaluation. The public availability of a real-world ICU database of multi-parameter physiologic waveforms, together with their associated annotated alarms is a new and valuable research resource for algorithm developers.
منابع مشابه
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملSignal quality and data fusion for false alarm reduction in the intensive care unit.
Due to a lack of integration between different sensors, false alarms (FA) in the intensive care unit (ICU) are frequent and can lead to reduced standard of care. We present a novel framework for FA reduction using a machine learning approach to combine up to 114 signal quality and physiological features extracted from the electrocardiogram, photoplethysmograph, and optionally the arterial blood...
متن کاملReduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure.
The paper presents an algorithm for reducing false alarms related to changes in arterial blood pressure (ABP) in intensive care unit (ICU) monitoring. The algorithm assesses the ABP signal quality, analyses the relationship between the electrocardiogram and ABP using a fuzzy logic approach and post-processes (accepts or rejects) ABP alarms produced by a commercial monitor. The algorithm was dev...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical informatics
دوره 41 3 شماره
صفحات -
تاریخ انتشار 2008