Clinical implementation of multisequence MRI‐based adaptive intracavitary brachytherapy for cervix cancer

نویسندگان

  • Jacqueline E. Zoberi
  • Jose Garcia‐Ramirez
  • Yanle Hu
  • Baozhou Sun
  • Carol G. Bertelsman
  • Pawel Dyk
  • Julie K. Schwarz
  • Perry W. Grigsby
چکیده

The purpose of this study was to describe the clinical implementation of a magnetic resonance image (MRI)-based approach for adaptive intracavitary brachytherapy (ICBT) of cervix cancer patients. Patients were implanted with titanium tandem and colpostats. MR imaging was performed on a 1.5-T Philips scanner using T2-weighted (T2W), proton-density weighted (PDW), and diffusion-weighted (DW) imaging sequences. Apparent diffusion coefficient (ADC) maps were generated from the DW images. All images were fused. T2W images were used for the definition of organs at risk (OARs) and dose points. ADC maps in conjunction with T2W images were used for target delineation. PDW images were used for applicator definition. Forward treatment planning was performed using standard source distribution rules normalized to Point A. Point doses and dose-volume parameters for the tumor and OARs were exported to an automated dose-tracking application. Brachytherapy doses were adapted for tumor shrinkage and OAR variations during the course of therapy. The MRI-based ICBT approach described here has been clinically implemented and is carried out for each brachytherapy fraction. Total procedure time from patient preparation to delivery of treatment is typically 2 hrs. Implementation of our tech-nique for structure delineation, applicator definition, dose tracking, and adaptation is demonstrated using treated patient examples. Based on published recommendations and our clinical experience in the radiation treatment of cervix cancer patients, we have refined our standard approach to ICBT by 1) incorporating a multisequence MRI technique for improved visualization of the target, OARs, and applicator, and by 2) implementing dose adaptation by use of automated dose tracking tools.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of trans-applicator intracavitary ultrasonography in brachytherapy for cervical cancer: phantom study of a novel approach to 3D image-guided brachytherapy

PURPOSE To assess the feasibility of applying trans-applicator intracavitary ultrasonography to image-guided brachytherapy for cervical cancer. MATERIAL AND METHODS For this experiment, a phantom was created and included a polyethylene tube, intended to simulate a tandem applicator, which was inserted into chicken meat and embedded in agar, along with magnetic resonance imaging (MRI)-compatib...

متن کامل

A new template for MRI-based intracavitary/interstitial gynecologic brachytherapy: design and clinical implementation

PURPOSE To describe the potential clinical use of a new brachytherapy applicator for gynecological tumors, with special attention to locally advanced cervical carcinoma. This device allows the combination of intracavitary radiotherapy and MRI-compatible transperineal interstitial needles. The design of this template addresses the disadvantages of currently commercially available templates: the ...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

Image-guided high-dose-rate intracavitary brachytherapy in the treatment of medically inoperable early-stage endometrioid type endometrial adenocarcinoma.

PURPOSE The purpose of this case series is to describe the treatment and outcomes of a cohort of patients with inoperable early-stage endometrioid endometrial cancer with 3D image-guided high-dose-rate (HDR) intracavitary brachytherapy. MATERIALS AND METHODS A review was performed of patients with early-stage endometrial cancer who underwent primary radiation treatment between 2010 and 2016. ...

متن کامل

MRI in intracavitary brachytherapy planning for cervical cancer malignancy, the pitfalls and complications

Learning objectives Discuss the role and benefits of MRI in planning for brachytherapy treatment in cervical cancer. Discuss the key mechanisms of the applicator and the technical aspects of planning brachytherapy. Discuss the role of MRI imaging in recognising the features of appropriate applicator placement and common complications. Review key MRI features of radiation-related alterations in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016