Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

نویسندگان

  • André Walter
  • Heinz Winsauer
  • Jordi Marcé-Nogué
  • Sergi Mojal
  • Andreu Puigdollers
چکیده

OBJECTIVE Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. MATERIAL AND METHODS Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bottom at 8 mm depth was reached. OMI designs were analyzed with a scan electron microscope (SEM). RESULTS SEM images revealed a great variation in product refinement. In the whole sample, a cylindrical OMI shape was associated with higher POS (p<0.001) but lower IT (p=0.002) values. The outer and inner OMI diameters were design characteristics well correlated with POS, IT and TF values (ranging from 0.601 to 0.961). Greater thread depth was related to greater POS values (r= 0.628), although OMIs with similar POS values may have different IT values. Thread depth and pitch had some impact on POS. TF depended mainly on the OMI inner (r= 0.961) and outer diameters (r=0.892). A thread depth to outer diameter ratio close to 40% increased TF risk. CONCLUSION Although at the same insertion depth the OMI outer and inner diameters are the most important factors for primary stability, other OMI design characteristics (cylindrical vs. conical, thread design) may significantly affect primary stability and torsional fracture. This needs to be considered when selecting the appropriate OMI for the desired orthodontic procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Thread Design of Orthodontics Mini Implants on Their Stability - A Pilot Study

ObjectivesThis FEM study was conducted in order to investigate the effect of thread design of an orthodontic mini-implant on primary stability and strain pattern and magnitude in the surrounding bone structure during orthodontic loading. Materials and MethodsThe mini-implants by six different manufacturers such as Aarhus Mini-Implant (American Orthodontics), AbsoAnchor (Dentos), Dual-Top (Jeil ...

متن کامل

Fracture strength of orthodontic mini-implants

Objective: This study aimed at evaluating the design and dimensions of five different brands of orthodontic mini-implants, as well as their influence on torsional fracture strength. Methods: Fifty mini-implants were divided into five groups corresponding to different manufactures (DEN, RMO, CON, NEO, SIN). Twenty-five mini-implants were subjected to fracture test by torsion in the neck and t...

متن کامل

Primary stability of orthodontic mini-implants inserted into maxilla and mandible of swine.

OBJECTIVE The objective of this study was to assess the primary stability of different orthodontic mini-implants inserted into different maxillary and mandibular regions of swine. MATERIAL AND METHODS One hundred eighty orthodontic mini-implants produced by 5 different manufacturers, all presenting several shapes, were divided into 5 groups: Mondeal (M), Neodent (N), SIN (S), INP, and Titaniu...

متن کامل

Metallographic analysis of the internal microstructure of orthodontic mini-implants.

Effective orthodontic anchorage may be obtained by miniimplants inserted into the maxillary bones. However, the risk of miniimplant failure is one of the most important issues, especially the rupture of its structure referred to as fracture, mainly due to metal deficiencies. This study analyzed the internal microstructure of orthodontic mini-implants, ascertaining the composition of the metal t...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2013