Estimation of Baseline Drifts in fMRI
نویسندگان
چکیده
This work provides a new method to estimate and remove baseline drifts in the fMRI signal. The baseline drift in each time series is described as a superposition of physical and physiological phenomena that occur at different scales. A fast algorithm, based on a wavelet representation of the data yields detrended time-series. Experiments with fMRI data demonstrate that our detrending technique can infer and remove drifts that cannot be adequately represented with low degree polynomials. Our detrending technique resulted in a noticeable improvement by reducing the number of false positive and the number of false negative.
منابع مشابه
Physiological origin of low-frequency drift in blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI).
We investigated the biophysical mechanism of low-frequency drift in blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) (0.00-0.01 Hz), by exploring its spatial distribution, dependence on imaging parameters, and relationship with task-induced brain activation. Cardiac and respiratory signals were concurrently recorded during MRI scanning and subsequently removed fr...
متن کاملReducing Effects of Drift in fMRI Data Using Joint Reconstruction of R2* and Field Maps
Introduction In blood oxygenation level dependent (BOLD) functional MRI (fMRI), linear signal drifts are often seen in the time series. These drifts are nuisance parameters that are either regressed or filtered out when performing the functional analysis. The largest sources are believed to be scanner instability such as B0 drift and physiological noise and motion [1]. B0 drift also causes drif...
متن کاملDetection and detrending in fMRI data analysis.
This article addresses the impact that colored noise, temporal filtering, and temporal detrending have on the fMRI analysis situation. Specifically, it is shown why the detection of event-related designs benefit more from pre-whitening than blocked designs in a colored noise structure. Both theoretical and empirical results are provided. Furthermore, a novel exploratory method for producing dri...
متن کاملCamera Pose Estimation in Unknown Environments using a Sequence of Wide-Baseline Monocular Images
In this paper, a feature-based technique for the camera pose estimation in a sequence of wide-baseline images has been proposed. Camera pose estimation is an important issue in many computer vision and robotics applications, such as, augmented reality and visual SLAM. The proposed method can track captured images taken by hand-held camera in room-sized workspaces with maximum scene depth of 3-4...
متن کاملThe Relationship Between M in “Calibrated fMRI” and the Physiologic Modulators of fMRI
The "calibrated fMRI" technique requires a hypercapnia calibration experiment in order to estimate the factor "M". It is desirable to be able to obtain the M value without the need of a gas challenge calibration. According to the analytical expression of M, it is a function of several baseline physiologic parameters, such as baseline venous oxygenation and CBF, both of which have recently been ...
متن کامل