The reliability of measuring left ventricular ejection fraction by radionuclide cardiography: evaluation by the method of variance components.

نویسندگان

  • P F Høilund-Carlsen
  • S L Lauritzen
  • J Marving
  • S Rasmussen
  • B Hesse
  • K Folke
  • J Godtfredsen
  • B Chraemmer-Jørgensen
  • N Gadsbøll
  • H Dige-Petersen
چکیده

A statistical model based on the method of variance components was applied to obtain confidence statements for single and repeat determinations of left ventricular ejection fraction by radionuclide techniques. With this approach variance caused by individual factors in the measurement procedure is estimated to allow calculation of confidence intervals based on single measurements and the detection limits for changes. Six study groups made up of a total of 143 subjects were examined by both multigated equilibrium and first pass imaging. Under favourable conditions (with an updated gamma camera and experienced observer) the 95% confidence interval with a single measurement of left ventricular ejection fraction by equilibrium imaging was +/- 3 ejection fraction units, compared with +/- 6 units with the first pass technique (one ejection fraction unit = 1/100 of the possible values from 0.00 to 1.00). The minimal significant changes (at the 5% level) in measured equilibrium left ventricular ejection fraction at intervals of 15 min, 3 days, 1, 3, and 4 weeks were +/- 4, +/- 4, +/- 5, +/- 5, and +/- 6 units, respectively. The corresponding minimal detectable changes in a subject's "true" left ventricular ejection fraction for the same intervals were +/- 7, +/- 7, +/- 10, +/- 10, and +/- 12 units respectively. With first pass imaging, only average values for the variation at repeat determination could be calculated. The minimal significant change in measured first pass left ventricular ejection fraction was +/- 7 units, and the minimal detectable change in "true" left ventricular ejection fraction was +/- 14 units. Measurements of left ventricular ejection fraction by equilibrium technique were generally more reproducible than first pass determinations because the variability caused by study acquisition, observer analysis, and residual errors was smaller. The method of variance components appears to be well suited to the evaluation of quantitative biological measurements in clinical use. The popularity of established procedures may obscure the lack of basic information about method evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Evaluation of Cardiac Function in Patients with Thalassemia Intermedia

Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...

متن کامل

Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method

Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...

متن کامل

The Relation between Left Ventricular Function and Serum Ferritin in Major Β-Thalassemia

Abstract Objective Cardiac dysfunction is a major cause of death in patients with beta thalassemia. In these patients, repeated blood transfusion, ineffective erythropoiesis and increased gastrointestinal iron absorption lead to iron overload in the body and this induced heart failure. Left ventricular ejection fraction was measured in major beta thalassemia (β-Th) patients to detect the rela...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 59 6  شماره 

صفحات  -

تاریخ انتشار 1988