A recoil resilient lumen support, design, fabrication and mechanical evaluation

نویسندگان

  • Arash Mehdizadeh
  • Mohamed Sultan
  • Mohamed Ali
  • Kenichi Takahata
  • Said Al-Sarawi
  • Derek Abbott
چکیده

Stents are artificial implants that provide scaffolding to a cavity inside the body. This paper presents a new luminal device for reducing the mechanical failure of stents due to recoil, which is one of the most important issues in stenting. This device, which we call a recoil-resilient ring (RRR), is utilized standalone or potentially integrated with existing stents to address the problem of recoil. The proposed structure aims to minimize the need for high-pressure overexpansion that can induce intra-luminal trauma and excess growth of vascular tissue causing later restenosis. The RRR is an overlapped open ring with asymmetrical sawtooth structures that are intermeshed. These teeth can slide on top of each other, while the ring is radially expanded, but interlock step-by-step so as to keep the final expanded state against compressional forces that normally cause recoil. The RRRs thus deliver balloon expandability and, when integrated with a stent, bring both radial rigidity and longitudinal flexibility to the stent. The design of the RRR is investigated through finite element analysis (FEA), and then the devices are fabricated using micro-electro-discharge machining of 200-μm-thick Nitinol sheet. The standalone RRR is balloon expandable in vitro by 5–7 Atm in pressure, which is well within the recommended in vivo pressure ranges for stenting procedures. FEA compression tests indicate 13× less reduction of the cross-sectional area of the RRR compared with a typical stainless steel stent. These results also show perfect elastic recovery of the RRR after removal of the pressure compared to the remaining plastic deformations of the stainless steel stent. On the other hand, experimental loading tests show that the fabricated RRRs have 2.8× radial stiffness compared to a two-column section of a commercial stent while exhibiting comparable elastic recovery. Furthermore, testing of in vitro expansion in a mock artery tube shows around 2.9% recoil, approximately 5–11× smaller than the recoil reported for commercial stents. These experimental results demonstrate the effectiveness of the device design for the targeted luminal support and stenting applications. (Some figures may appear in colour only in the online journal)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Mechanical Properties of the cement treated Cold-in-Place Recycled Asphalt Mixtures

Cold-in-place recycling (CIR) is an environmentally sustainable alternative for preservation of asphalt pavements. A major disadvantage of this practice is the lower strength of the cold-in-place mixtures. Addition of cement into this type of mixture is a method for increasing its bearing capacity. The effect of cement content on the mechanical properties of the cold-in-place recycled asphalt m...

متن کامل

Early recoil after balloon angioplasty of tibial artery obstructions in patients with critical limb ischemia.

PURPOSE To assess the extent of early recoil in patients with critical limb ischemia (CLI) undergoing conventional tibial balloon angioplasty. METHODS Our hypothesis was that early recoil, defined as lumen compromise >10%, is frequent and accounts for considerable luminal narrowing after tibial angioplasty, promoting restenosis. To test this theory, 30 consecutive CLI patients (18 men; mean a...

متن کامل

Design, Fabrication and Intelligent Control of the Gripper Based on SMA Actuators

This paper presents the designing, simulation, fabrication and control of a gripper actuated by Shape Memory Alloy (SMA) wire. The presented gripper has the advantage of the small linear displacement of the slider connected to the SMA wire, and can convert the linear displacement into angular movement of the gripper fingers. In this study, design and simulation processes have been done by two p...

متن کامل

Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013