Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation.

نویسندگان

  • Hiroshi Kuroki
  • Setti S Rengachary
  • Vijay K Goel
  • Scott A Holekamp
  • Ville Pitkänen
  • Nabil A Ebraheim
چکیده

OBJECTIVE To compare the biomechanical stability imparted to the C1 and C2 vertebrae by either transarticular screw fixation (TSF) or screw and rod fixation (SRF) techniques in a cadaver model. METHODS Ten fresh ligamentous human cervical spine specimens were harvested from cadavers. The specimens were tested sequentially in the intact state, after injury and stabilization (unilateral left side and bilateral), and after fatiguing to 5000 cycles (0.5 Hz) at +/-1.0 N.m of flexion and extension. The specimens were stabilized by use of TSF in 5 spines or SRF in the other 5 spines. The data were converted to angular displacements, and the stabilized cases were compared with intact states for evaluating the efficacies of the two techniques in stabilizing the C1-C2 segments. RESULTS In the TSF group, the unilateral fixation using one screw imparted a significant stability in only the axial rotation mode. The unilateral procedure in the SRF group was effective in stabilization in all modes except in extension. The bilateral procedure in both of the groups was effective across the C1-C2 segment. However, the SRF group afforded higher stability than the corresponding TSF group in the flexion and extension modes. The degree of stability did not change after fatigue compared with the prefatigue data. CONCLUSION In general, a surgeon should undertake a bilateral fixation to achieve sufficient stability across the atlantoaxial complex, and either technique will provide satisfactory results, although the SRF technique may be better in the flexion and extension modes. One should use the SRF procedure while trying to achieve stability with a unilateral system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques.

STUDY DESIGN Six different techniques for atlantoaxial fixation were biomechanically compared in vitro by nondestructive testing. OBJECTIVE To evaluate the immediate three-dimensional stability of a new atlas claw combined with transarticular screws and alternative techniques for transarticular screw fixation in comparison with established techniques. SUMMARY OF BACKGROUND DATA Posterior tr...

متن کامل

Biomechanical analysis comparing three C1-C2 transarticular screw salvaging fixation techniques.

STUDY DESIGN This is an in vitro biomechanical study. OBJECTIVE To compare the biomechanical stability of the 3 C1-C2 transarticular screw salvaging fixation techniques. SUMMARY AND BACKGROUND DATA Stabilization of the atlantoaxial complex is a challenging procedure because of its complicated anatomy. Many posterior stabilization techniques of the atlantoaxial complex have been developed wi...

متن کامل

Biomechanical comparison of C1-C2 posterior arthrodesis techniques.

STUDY DESIGN Biomechanical comparison of 5 atlantoaxial posterior arthrodesis techniques. OBJECTIVE To assess the relative value of different posterior wire constructs when one or two transarticular screws are used. SUMMARY OF BACKGROUND DATA A combination of Gallie or Brooks techniques and 2 posterior transarticular screws has been shown to be effective for atlantoaxial arthrodesis. Anatom...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

A biomechanical comparison of a novel thoracic screw fixation method: transarticular screw fixation vs traditional pedicle screw fixation.

BACKGROUND Transarticular screw fixation is used in the upper cervical and lumbar spine to achieve posterior spinal stability, and its biomechanical performance has been proven to be similar to that of pedicle screw fixation. However, few studies have reported the use of transarticular screw fixation in the upper thoracic spine. OBJECTIVE To biomechanically compare transarticular screws with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Neurosurgery

دوره 56 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2005