Self-Tuning Fuzzy Control for Seismic Protection of Smart Base-Isolated Buildings Subjected to Pulse-Type Near-Fault Earthquakes
نویسندگان
چکیده
Pulse-type near-fault earthquakes have obvious long-duration pulses, so they can cause large deformation in a base-isolated system in contrast to non-pulse-type near-fault and far-field earthquakes. This paper proposes a novel self-tuning fuzzy logic control strategy for seismic protection of a base-isolated system, which can operate the control force of the piezoelectric friction damper against different types of earthquakes. This control strategy employs a hierarchic control algorithm, in which a higher-level supervisory fuzzy controller is implemented to adjust the input normalization factors and output scaling factor, while a sub-level fuzzy controller effectively determines the command voltage of the piezoelectric friction damper according to current level of earthquakes. The efficiency of the proposed control strategy is also compared with uncontrolled and maximum passive cases. Numerical results reveal that the novel fuzzy logic control strategy can effectively reduce the isolation system deformations without the loss of potential advantages of base-isolated system.
منابع مشابه
Structural control benchmark problem: Phase II—Nonlinear smart base-isolated building subjected to near-fault earthquakes
Many branches of engineering, mathematics, and sciences, have relied on benchmark problems as a standard means to compare different solution techniques. Since 1996, the ASCE Structural Control and Monitoring Committee and Task Group on Benchmark Problems, the U.S. Panel on structural control, and IASCM have developed a series of benchmark control problems that offer a set of carefully modeled r...
متن کاملSeismic response control of smart sliding isolated buildings using variable stiffness systems: an experimental and numerical study
E ectiveness of a new semiactive independently variable sti ness (SAIVS) device in reducing seismic response of sliding base isolated buildings is evaluated analytically and experimentally. Through analytical and experimental study of force—displacement behaviour of the SAIVS device, it is shown that the device can vary sti ness continuously and smoothly between minimum and maximum sti ness. Pa...
متن کاملAdaptive control of base-isolated structures against near-field earthquakes using variable friction dampers
This paper investigates the effectiveness of two adaptive control strategies for modulating control force of variable friction dampers (VFDs) that are employed as semi-active devices in combination with laminated rubber bearings for seismic protection of buildings. The first controller developed in this study is an adaptive fuzzy neural controller (AFNC). It consists of a direct fuzzy controlle...
متن کاملEvaluation of Nonlinear Response of Structures to Near-Fault Ground Motions and the Comparison of Results with Near-Fault Simulated Records
Near-fault ground motions have caused very much damage in the vicinity of seismic sources during recent earthquakes. It is well known that under specific circumstances, intensive ground shakings near fault ruptures may be characterized by short-duration impulsive motions. This pulse-type motion is generally particular to the forward direction, where the fault rupture propagates towards the site...
متن کاملSemiactive control strategy for a phase II smart base isolated benchmark building
This paper presents a semiactive control strategy for the seismic protection of the phase II smart base isolated benchmark building subjected to near-fault earthquakes. Magnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated buil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017