Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord.
نویسندگان
چکیده
A literature review of more than 200 stereotactic body radiation therapy spine articles from the past 20 years found only a single article that provided dose-volume data and outcomes for each spinal cord of a clinical dataset: the Gibbs 2007 article (Gibbs et al, 2007(1)), which essentially contains the first 100 stereotactic body radiation therapy (SBRT) spine treatments from Stanford University Medical Center. The dataset is modeled and compared in detail to the rest of the literature review, which found 59 dose tolerance limits for the spinal cord in 1-5 fractions. We partitioned these limits into a unified format of high-risk and low-risk dose tolerance limits. To estimate the corresponding risk level of each limit we used the Gibbs 2007 clinical spinal cord dose-volume data for 102 spinal metastases in 74 patients treated by spinal radiosurgery. In all, 50 of the patients were previously irradiated to a median dose of 40Gy in 2-3Gy fractions and 3 patients developed treatment-related myelopathy. These dose-volume data were digitized into the dose-volume histogram (DVH) Evaluator software tool where parameters of the probit dose-response model were fitted using the maximum likelihood approach (Jackson et al, 1995(3)). Based on this limited dataset, for de novo cases the unified low-risk dose tolerance limits yielded an estimated risk of spinal cord injury of ≤1% in 1-5 fractions, and the high-risk limits yielded an estimated risk of ≤3%. The QUANTEC Dmax limits of 13Gy in a single fraction and 20Gy in 3 fractions had less than 1% risk estimated from this dataset, so we consider these among the low-risk limits. In the previously irradiated cohort, the estimated risk levels for 10 and 14Gy maximum cord dose limits in 5 fractions are 0.4% and 0.6%, respectively. Longer follow-up and more patients are required to improve the risk estimates and provide more complete validation.
منابع مشابه
Clinical applicability of biologically effective dose calculation for spinal cord in fractionated spine stereotactic body radiation therapy
BACKGROUND The aim of the study was to investigate whether biologically effective dose (BED) based on linear-quadratic model can be used to estimate spinal cord tolerance dose in spine stereotactic body radiation therapy (SBRT) delivered in 4 or more fractions. PATIENTS AND METHODS Sixty-three metastatic spinal lesions in 47 patients were retrospectively evaluated. The most frequently prescri...
متن کاملDosimetric analysis of varying cord planning organ at risk volume in spine stereotactic body radiation therapy
BACKGROUND Spine stereotactic body radiation therapy (SBRT) is becoming widely accepted as first-line treatment of oligometastatic spine disease as well as in the postoperative setting. The reported incidence of myelopathy is very low and guidelines vary widely on the maximum tolerable dose of the spinal cord and thecal sac. METHODS AND MATERIALS Between April 2008 and December 2010, radiatio...
متن کاملEvaluating Published Skin Dose Tolerance Limits for Stereotactic Body Radiation Therapy of Lung Cancer
Objectives: Published local control rates for certain stereotactic body radiotherapy (SBRT) lung cancer treatments have exceeded 97%, but several serious adverse events have been reported. No five-year normal tissue complication probability (NTCP) statistical analysis SBRT results have been published yet for skin. While we expectantly await these publications, the goal of this manuscript is to ...
متن کاملLow toxicity for lung tumors near the mediastinum treated with stereotactic body radiation therapy.
PURPOSE To report the local control, survival, and low toxicity observed at the Cooper University Hospital CyberKnife Center post stereotactic body radiation therapy (SBRT) in the treatment of lung tumors near the mediastinum. METHODS AND MATERIALS Twenty-four medically inoperable lung cancer patients with tumors near the mediastinum were treated using the Accuray CyberKnife system (Accuray, ...
متن کاملThe comparison of dose distribution of different 3D conformal and conventional radiotherapy plans for gastric cancer
Aims: It was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. Methods: This study was conducted on the CT simulation images of thirty patients diagnosed with gastric cancer. Target volumes and the organs at risk were contoured. AP-PA reciprocal parallel field conventional plan an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Seminars in radiation oncology
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2016