Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier
نویسنده
چکیده
The portable germanium detector based HHRIDs are generally intended to be operated in low to medium radiation fields with as much sensitivity as possible. However, in some circumstances the interfering radioactive background may be significant with respect to the source of interest. For example: a shipping container full of NORM may be used in an attempt to mask the presence of a concealed SNM source. It is therefore often desirable to examine only one area, object or container at a time to localize a source in a searching operation. To do this, it is helpful to restrict the field of view of the instrument by collimation. Previous work showed the performance of two simple collimators (tungsten and steel) to be somewhat ineffective in reducing high energy (>1 MeV) gamma rays and that the tungsten fluorescence (59.3 keV) caused false positive misidentifications. A new graded-Z collimator was constructed of tungsten, tin and copper. The performance of this collimator was measured for all angles and for multiple energies to determine its effectiveness in reducing the count rate from material beyond the desired field of view. Results show the sensitivity for off-axis positions to be improved when locating a particular nuclide source in an area where other significant radioactive materials are present.
منابع مشابه
Standoff Performance of HPGe Detectors in Identification of Gamma-Ray Radiation Sources
The detection and identification of radiation sources at distances in the range of 15 meters or more is becoming increasingly important for illicit materials interdiction and the location of lost or orphan sources. In most locations, there is a considerable gamma-ray flux from natural background (NORM) and cosmic-induced nuclides. This gamma-ray flux varies with time, weather conditions, locati...
متن کاملHigh Resolution Detection Systems for Interdiction of Nuclear Material Trafficking
The interdiction of nuclear materials during illegal transportation requires both detection of radiation and identification of radionuclides in order to distinguish among the various categories of nuclides and their implied threat. Interdiction regimes, based upon available technologies, were developed rapidly after the tragic events of 9-11. In general, a low resolution or "no-resolution" port...
متن کاملPerformance of a Portable, Electromechanically-Cooled HPGe Detector for Site Characterization
High-resolution, germanium detectors (HPGe) have long been used for radionuclide characterization of nuclear sites, both buildings and large areas, for the purpose of cleaning up the site. Several systems consisting of a detector, mobile support, collimators and software for data collection and spectrum analysis have been made by national laboratories and commercial companies. The efficacy of t...
متن کاملUsing 137Cs Technique to Investigate Soil Redistribution Rates by Portable HPGe (Case Studies, Kachik Paired Subcatchments)
137Cs technique for determining soil particles redistribution is of tremendous importance considered by most soil and water conservation experts. Due to time and monetary limitations for spectrometry in the lab, a portable High Pure Germanium Detector was used in this study. For this, Kachik paired subcatchments were chosen and 60 positions in each subcatchment were used for spectrometry analys...
متن کاملINNM 2012 Field of View Measurements on a Collimated Transportable HPGe System Used in Search Systems
Mobile search systems are used to locate and identify radioactive material as the system is transported along a path. Both low and high resolution detectors are used in these systems. Low resolution detectors are often overwhelmed by high NORM background to the extent that the source signal is hidden. High resolution germanium detectors are more selective with easily identifiable peaks and the ...
متن کامل