Assessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy
نویسنده
چکیده
Filtered back projection (FBP) method and maximum likelihood expection maximization (OSEM) method are currently used for reconstruction of SPECT images in clinical studies. The aim of this work is to compare the image quality using different reconstruction techniques of a SPECT phantom as applied to bone scintigraphy. The resolution and contrast of the hot spheres were observed using a phantom insert with OSEM and FBP techniques. The activity profile, drown through the hot spheres demonstrates that the FBP image is often blurred and more noisy than the image which reconstructed iteratively using OSEM. This means that there is an improvement in resolution of the image with OSEM reconstruction technique. There is a decreasing in counts of reconstructed slices by FBP technique and increase in counts of the same reconstructed slices by OSEM technique. This shows an improvement in image quality and increased accuracy of the OSEM, technique to its algorithm accuracy. Thus OSEM can replace the FBP technique for its merits.
منابع مشابه
Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملComparison of image reconstruction algorithms in myocardial perfusion scintigraphy.
The purpose of this study was to compare the clinical utility of two image reconstruction algorithms in myocardial perfusion SPECT (single-photon emission computed tomography): filtered back-projection (FBP) and ordered subset expectation maximization (OSEM). A rest/stress one-day protocol with 99mTc-MIBI or tetrofosmin was performed on 102 consecutive patients who underwent coronary angiograph...
متن کاملQuantification and optimisation of lung ventilation SPECT images
................................................................................................................... 1 SAMMANFATTNING ................................................................................................... 3 LIST OF PAPERS ........................................................................................................... 5 ABBREVIATIONS ..........................
متن کاملPerformance Evaluation of FBP Reconstruction in SPECT Imaging
Introduction: The purpose of this study is to define the optimal parameters for the tomographic reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional conformation and the results were compared. Materials and Methods: The 2D phant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010