True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI
نویسندگان
چکیده
Background SMART1Map is a new single-point technique for cardiac T1 mapping [1]. Unlike Look-Locker approaches, such as MOLLI, which yield an “apparent” T1 (T1*), SMART1Map directly measures true T1. Because T1* is a function of imaging parameters, it is always shorter than T1, and correction methods are required to obtain the true T1. This work compared the accuracy of SMART1Map with MOLLI in phantom experiments under several imaging conditions.
منابع مشابه
Myocardial T1 mapping using SMART1Map: initial in vivo experience
Background Recently a single-point, saturation-recovery myocardial T1 mapping sequence (SMART1Map = Saturation Method using Adaptive Recovery Times for cardiac T1 Mapping) was presented [1]. Compared to common methods like MOLLI, SMART1Map measures true T1 instead of apparent T1 relaxation, is more time efficient and can track exact TI times instead of estimated ones based on the heart rate dur...
متن کاملA long way from the heart.
the gadolinium-enhanced myocardium: adjustment for factors affecting interpatient comparison. Magn Reson Med 2011;65:1407–15. 21. Schneider CA,Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 yearsof image analysis. Nat Methods 2012;9:671–5. 22. Flett AS, Hayward MP, Ashworth MT, Hansen MS, Taylor AM, Elliott PM et al. Equilibrium contrast cardiovascular magnetic resonance for the measurement o...
متن کاملComparing the accuracy and precision of SMART1Map, SASHA and MOLLI
Background Currently, MOLLI [1] is the most common method for measuring myocardial T1. Because MOLLI uses an SSFP-based Look-Locker approach, only the apparent T1 (T1*) can be measured, and there are concerns about the accuracy of the T1* values due to the dependence on imaging parameters. Alternatives to LookLocker imaging are single-point methods such as SASHA[2] and SMART1Map[3]. Although si...
متن کاملMyocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI
BACKGROUND Myocardial T1-mapping recently emerged as a promising quantitative method for non-invasive tissue characterization in numerous cardiomyopathies. Commonly performed with an inversion-recovery (IR) magnetization preparation at 1.5T, the application at 3T has gained due to increased quantification precision. Alternatively, saturation-recovery (SR) T1-mapping has recently been introduced...
متن کاملHeart-rate independent myocardial T1-mapping using combined saturation and inversion preparation pulses
Background Myocardial T1 mapping remains a challenging task due to restrictions imposed by cardiac and respiratory motion. Modified Look-Locker Inversion Recovery (MOLLI) [1] is widely used for 2D cardiac T1-mapping. In MOLLI, the spin-lattice relaxation curve is sampled several times after a single magnetization preparation. The ECG triggered imaging induces a disturbance in the relaxation cur...