A closed circuit apparatus for measurement of oxygen consumption in small animals.

نویسندگان

  • D V Muralidhara
  • P S Shetty
چکیده

A simple and reliable closed circuit apparatus for short term and long term measurements of oxygen consumption of small laboratory animals is described. Repeat measurements of oxygen consumption under resting conditions of six male albino rats using this apparatus shows a variability of less than 1.5%. Use of the set-up for continuous monitoring of oxygen consumption following subcutaneous injection of norepinephrine, for over 2.5 hr enables the measurement of energy expenditure in animals on a long term basis which is reproducible on several occasions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy Expenditure During Singing: A Reply to Gaunt et al

DEPOCAS, F. AND J. S. HART. 1957. Use of the Pauling oxygen analyzer for measurement of oxygen consumption of animals in open-circuit systems and in a short-lag closed-circuit apparatus. Journal of Applied Physiology 10:388-392. EEERHARDT, L.S. 1994. Oxygen consumption during singing by male Carolina Wrens (Thryothorus ludovicianus). Auk 111:124-130. FRAPPELL, P. B., H. A. BLEVIN, AND R. V. BAU...

متن کامل

Oxygen consumption measurement: agreement between the closed-circuit PhysioFlex anesthesia machine and the Deltatrac II indirect calorimeter.

UNLABELLED We designed this study to ascertain whether, for the purpose of clinical interpretation, the direct measurement of O(2) consumption with the PhysioFlex closed-circuit anesthesia machine and with the Deltatrac II indirect calorimeter are interchangeable. Oxygen consumption was measured using the two instruments successively in critically-ill, mechanically-ventilated patients. Measurem...

متن کامل

A Respiration Chamber for Cattle

Traditional methods for measurement of gas exchange in domestic animals utilize the open-circuit principle in which a known flow of air is drawn past the animal and its change in composition is measured; or the closed-circuit principle in which. carbon dioxide is absorbed and weighed and oxygen is metered into the system. The open-circuit chamber has an exact counterpart in a mask method and th...

متن کامل

Respirometry: correcting for diffusion and validating the use of plastic multiwell plates with integrated optodes.

Polystyrene multiwell plates with integrated optodes act as multiple closed-system respirometers that enable the simultaneous measurement of oxygen consumption in small animals. However, the diffusion of oxygen through polystyrene needs to be taken into consideration. Here we provide an equation that accounts for the empirically determined rate of oxygen through a polystyrene well when calculat...

متن کامل

Oxygen and nitrous oxide uptake during general anesthesia for cardiac catheterization in infants with congenital heart disease.

monary hyperventilation using a closed circuit apparatus designed for this purpose. A highly significant relation was found between oxygen uptake and patient surface area given by the regression equation V2=i6-5 (body weight in kg)213-3.8 ml/min (mean V02= I65 mll minIm2), and between VO2 and body weight given by V°2= 6-74e0076kg+ 4* Values for T02 kg variedfrom Io ml/min per kg to 5 ml/min per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian journal of physiology and pharmacology

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 1983