Deconvolution of Images Taken with the Suzaku X-ray Imaging Spectrometer

نویسندگان

  • Mutsumi Sugizaki
  • Yoshitomo Maeda
چکیده

We present a non-iterative method to deconvolve the spatial response function or the point spread function (PSF) from images taken with the Suzaku X-ray Imaging Spectrometer (XIS). The method is optimized for analyses of extended sources with high photon statistics. Suzaku has four XIS detectors each with its own X-ray CCD and X-Ray Telescope (XRT) and has been providing unique opportunities in spatiallyresolved spectroscopic analyses of extended objects. The detectors, however, suffer from broad and position-dependent PSFs with their typical half-power density (HPD) of about 110. In the authors’ view, this shortcoming has been preventing the high collecting area and high spectral resolution of Suzaku to be fully exploited. The present method is intended to recover spatial resolution to ∼ 15 over a dynamic range around 1:100 in the brightness without assuming any source model. Our deconvolution proceeds in two steps: An XIS image is multiplied with the inverse response matrix calculated from its PSF after rebinning CCD pixels to larger-size tiles (typically 6 × 6); The inverted image is then adaptively smoothed to obtain the final deconvolved image. The PSF is modeled on a ray-tracing program and an observed point-source image. The deconvolution method has been applied to images of Centaurus A, PSR B1509-58 and RCW 89 taken by one XIS (XIS-1). The results have been compared with images obtained with Chandra to conclude that the spatial resolution has been recovered to ∼ 20 down to regions where surface brightness is about 1:50 of the brightest tile in the image. We believe the spatial resolution and the dynamic range can be improved in the future with higher fidelity PSF modeling and higher precision pointing information.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

Detection of a Rare Supersoft Outburst Event during a Suzaku Observation of 1E 0102.2–7219

We report the detection of a transient X-ray source toward the Small Magellanic Cloud (SMC) using the X-ray Imaging Spectrometer (XIS) onboard the Suzaku telescope. The source was detected at the edge of the XIS image during a routine observation of the calibration source 1E 0102.2–7219, a supernova remnant in the SMC. We constrained the source position using ray-tracing simulations. No such tr...

متن کامل

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008