Analysis of Reflectance Photoplethysmograph Sensors
نویسندگان
چکیده
Photoplethysmography is a simple measurement of the variation in blood volume in tissue. It detects the pulse signal of heart beat as well as the low frequency signal of vasoconstriction and vasodilation. The transmission type measurement is limited to only a few specific positions for example the index finger that have a short path length for light. The reflectance type measurement can be conveniently applied on most parts of the body surface. This study analyzed the factors that determine the quality of reflectance photoplethysmograph signal including the emitter-detector distance, wavelength, light intensity, and optical properties of skin tissue. Light emitting diodes (LEDs) with four different visible wavelengths were used as the light emitters. A phototransistor was used as the light detector. A micro translation stage adjusts the emitter-detector distance from 2 mm to 15 mm. The reflective photoplethysmograph signals were measured on different sites. The optimal emitter-detector distance was chosen to have a large dynamic range for low frequency drifting without signal saturation and a high perfusion index. Among these four wavelengths, a yellowish green (571nm) light with a proper emitter-detection distance of 2mm is the most suitable for obtaining a steady and reliable reflectance photoplethysmograph signal Keywords—Reflectance photoplethysmograph, Perfusion index, Signal-to-noise ratio
منابع مشابه
In-Ear Pulse Wave Measurements: A Pilot Study.
The measurement of the Pulse wave Arrival Time (PAT) has proven to be a vital tool in medical diagnosis. Whereby most PAT measurements are carried out at extremities, this work proposes the interior of the ear as a new site. Due to pressure variations inside the auditory canal a pulse wave can be measured by using a pressure sensor or by simple in-ear headphones. To verify the signal origin, a ...
متن کاملPhotoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction
A new type of touch sensor for detecting contact pressure at human fingertips is presented. Unlike traditional electronic gloves, in which sensor pads are placed between the fingers and the environment surface, this new sensor allows the fingers to directly contact the environment without obstructing the human’s natural haptic senses. The finger touch force is detected by measuring changes in t...
متن کاملRespiration and Heart Rate Monitoring from Photoplethysmograph Signal
Photoplethysmograph is a simple and cost effective method to assess cardiovascular related parameters such as heart rate, arterial blood oxygen saturation, BP the fact that the Photoplethysmograph (PPG) signal caries respiratory information. Earlier physicians used to insert separate sensors to assess respiration and heart rate. In this present work, an efficient algorithm is presented, based o...
متن کاملغربالگری خودکار افراد خطاکار با تحلیل تفکیکپذیری مشخصات سیگنالهای هدایت الکتریکی پوست و حجمسنجی نوری
Credibility assessment screening by a small system and receiving optimum result in minimum time is a basic need in critical gates. Therefore the aim of this research is automatic detection of stress in guilty persons through skin conductance response and photoplethysmograph signals which are convenient and ease-of-use sensors .In this paper, a set of database with interview protocol (including ...
متن کاملHeart rate and blood pressure estimation from compressively sensed photoplethysmograph
In this paper we consider the problem of low power SpO2 sensors for acquiring Photoplethysmograph (PPG) signals. Most of the power in SpO2 sensors goes to lighting red and infra-red LEDs. We use compressive sensing to lower the amount of time LEDs are lit, thereby reducing the signal acquisition power. We observe power savings by a factor that is comparable to the sampling rate. At the receiver...