Further efforts to predict pure-tone thresholds from distortion product otoacoustic emission input/output functions.

نویسندگان

  • Michael P Gorga
  • Stephen T Neely
  • Patricia A Dorn
  • Brenda M Hoover
چکیده

Recently, Boege and Janssen [J. Acoust. Soc. Am. 111, 1810-1818 (2002)] fit linear equations to distortion product otoacoustic emission (DPOAE) input/output (UO) functions after the DPOAE level (in dB SPL) was converted into pressure (in microPa). Significant correlations were observed between these DPOAE thresholds and audiometric thresholds. The present study extends their work by (1) evaluating the effect of frequency, (2) determining the behavioral thresholds in those conditions that did not meet inclusion criteria, and (3) including a wider range of stimulus levels. DPOAE I/O functions were measured in as many as 278 ears of subjects with normal and impaired hearing. Nine f2 frequencies (500 to 8000 Hz in 1/2-octave steps) were used, L2 ranged from 10 to 85 dB SPL (5-dB steps), and L1 was set according to the equation L1 = 0.4L2 + 39 dB [Kummer et al., J. Acoust. Soc. Am. 103, 3431-3444 (1998)] for L2 levels up to 65 dB SPL, beyond which L1 = L2. For the same conditions as those used by Boege and Janssen, we observed a frequency effect such that correlations were higher for mid-frequency threshold comparisons. In addition, a larger proportion of conditions not meeting inclusion criteria at mid and high frequencies had hearing losses exceeding 30 dB HL, compared to lower frequencies. These results suggest that DPOAE I/O functions can be used to predict audiometric thresholds with greater accuracy at mid and high frequencies, but only when certain inclusion criteria are met. When the SNR inclusion criterion is not met, the expected amount of hearing loss increases. Increasing the range of input levels from 20-65 dB SPL to 10-85 dB SPL increased the number of functions meeting inclusion criteria and increased the overall correlation between DPOAE and behavioral thresholds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between DPOAE I/O functions and pure-tone thresholds.

UNLABELLED Different studies have been carried out in order to correlate audiometric thresholds and distortion product otoacoustic emissions measurements (DPOAE). However, high variability and external interferences make hearing thresholds estimates by means of the DPOAE very little sensitive. The aim of this study was to check the correspondence between the pure tone thresholds and the cochlea...

متن کامل

تأثیر مواجهه با نویز بر سیستم شنوایی کارگران با استفاده از ادیومتری تون خالص (PTA)، گسیل‌های صوتی گذرای گوش (TEOAEs) و گسیل‌های صوتی محصول اعوجاج (DPOAE)

 Background: Different studies have shown that Otoacoustic Emission (OAEs) is generated by Outer Hair Cells (OHCs) and these sensory cells are first structures exposed to damage of high level noise. Therefore minor impairment in OHCs can lead to lack of response of OAE. The purpose of the current study is to compare the pure tone thresholds, Transient Evoked Otoacoustic Emission (TEOAE...

متن کامل

Chapter 3: Parameters that Influence Pure Tone Threshold Prediction Accuracy with Distortion Product Otoacoustic Emissions and Artificial Neural Networks

The preceding chapter formulated the need for an objective audiologic procedure to aid in the assessment of difficult-to-test populations. Limitations in current objective procedures inspired the ongoing effort to attempt to predict pure tone thresholds (PITs) accurately across a wide frequency range. Despite the complex relation between DPOAEs and PTTs, many researchers turned to distortion pr...

متن کامل

Cochlear involvement in patients with ulcerative colitis.

OBJECTIVE To investigate whether cochlear involvement is an extraintestinal manifestation in patients with ulcerative colitis. METHOD Forty-four ulcerative colitis patients and 44 age-matched healthy subjects were included in the study. Pure tone and speech audiometry, and distortion product otoacoustic emission tests were performed on all participants. The audiometric test results were compa...

متن کامل

Comparison of Pure-Tone and Distortion Product Otoacoustic Emission Screenings in School-Age Children

The purpose of this study was to compare the outcome of a distortion product otoacoustic emission (DPOAE) screening to the outcome of a pure-tone hearing screening for school-age children. Participants included 565 children in kindergarten through second grade in central Arkansas. Data were analyzed on a total of 547 participants. A McNemar Chi-square test [χ2 (1, N=547) =2.06; p=.151)] reveale...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 113 6  شماره 

صفحات  -

تاریخ انتشار 2003