X-ray exposure hazards for physicians performing ablation procedures and device implantation: results of the European Heart Rhythm Association survey.
نویسندگان
چکیده
The purpose of the survey was to evaluate physician's and authorities policies and clinical practices when using occupational X-ray during ablation procedures and device implantation. This survey shows infrequent use of lead gloves, radiation absorbing pads, and lead glass cabins, but increasing use of three-dimensional mapping systems to decrease X-ray radiation hazards. Digital fluoroscopy with decreased frame rate is not used by approximately one-third of responding centres.
منابع مشابه
Use of fluoroscopy in clinical electrophysiology in Europe: results of the European Heart Rhythm Association Survey.
Despite the advent of non-fluoroscopic technologies, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies to ablation interventions and device implantation. The purpose of the European Heart Rhythm Association survey was to provide an insight into regulatory policies and physicians' clinical practice when using fluoroscop...
متن کاملPersonnel, equipment, and facilities for electrophysiological and catheter ablation procedures in Europe: results of the European Heart Rhythm Association Survey.
Clinical electrophysiology (EP) and catheter ablation of arrhythmias are rapidly evolving in recent years. More than 50 000 catheter ablations are performed every year in Europe. Emerging indications, an increasing number of procedures, and an expected high quality require national and international standards as well as trained specialists. The purpose of this European Heart Rhythm Association ...
متن کاملPreferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association survey.
The aim of this European Heart Rhythm Association (EHRA) survey was to assess clinical practice in relation to the tools and techniques used for cardiac implantable electronic devices procedures in the European countries. Responses to the questionnaire were received from 62 members of the EHRA research network. The survey involved high-, medium-, and low-volume implanting centres, performing, r...
متن کاملPeriprocedural anticoagulation therapy for devices and atrial fibrillation ablation.
This EP Wire surveyed clinical practice with regard to the use of antithrombotic therapy in relation to device implantation (pacemakers, ICT, resynchronization therapy) and atrial fibrillation ablation in 71 centres-members of the European Heart Rhythm Association research network. The results of this survey show variation in clinical practice, but reassuringly some consistency with guidelines ...
متن کاملHow are arrhythmias managed in the paediatric population in Europe? Results of the European Heart Rhythm survey.
The aim of this survey was to provide insight into current practice regarding the management of paediatric arrhythmias in Europe. The survey was based on a questionnaire sent via the Internet to the European Heart Rhythm Association (EHRA) electrophysiology research network centres. The following topics were explored: patient and treatment selection, techniques and equipment, treatment outcomes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2013