Development and validation of a rapid and robust method to determine visceral adipose tissue volume using computed tomography images

نویسندگان

  • Aaroh M. Parikh
  • Adriana M. Coletta
  • Z. Henry Yu
  • Gaiane M. Rauch
  • Joey P. Cheung
  • Laurence E. Court
  • Ann H. Klopp
چکیده

BACKGROUND Visceral adiposity is a risk factor for many chronic diseases. Existing methods to quantify visceral adipose tissue volume using computed tomographic (CT) images often use a single slice, are manual, and are time consuming, making them impractical for large population studies. We developed and validated a method to accurately, rapidly, and robustly measure visceral adipose tissue volume using CT images. METHODS In-house software, Medical Executable for the Efficient and Robust Quantification of Adipose Tissue (MEERQAT), was developed to calculate visceral adipose tissue volume using a series of CT images within a manually identified region of interest. To distinguish visceral and subcutaneous adipose tissue, ellipses are drawn through the rectus abdominis and transverse abdominis using manual and automatic processes. Visceral and subcutaneous adipose tissue volumes are calculated by counting the numbers of voxels corresponding to adipose tissue in the region of interest. MEERQAT's ellipse interpolation method was validated by comparing visceral adipose volume from 10 patients' CT scans with corresponding results from manually delineated scans. Accuracy of visceral adipose quantification was tested using a phantom consisting of animal fat and tissues. Robustness of the method was tested by determining intra-observer and inter-observer coefficients of variation (CV). RESULTS The mean difference in visceral adipose tissue volume between manual and elliptical delineation methods was -0.54 ± 4.81%. In the phantom, our measurement differed from the known adipose volume by ≤ 7.5% for all scanning parameters. Mean inter-observer CV for visceral adipose tissue volume was 0.085, and mean intra-observer CV for visceral adipose tissue volume was 0.059. CONCLUSIONS We have developed and validated a robust method of accurately and quickly determining visceral adipose tissue volume in any defined region of interest using CT imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...

متن کامل

A Method for Body Fat Composition Analysis in Abdominal Magnetic Resonance Images Via Self-Organizing Map Neural Network

Introduction: The present study aimed to suggest an unsupervised method for the segmentation of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) in axial magnetic resonance (MR) images of the abdomen. Materials and Methods: A self-organizing map (SOM) neural network was designed to segment the adipose tissue from other tissues in the MR images. The segmentation of SAT and VA...

متن کامل

Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Does measurement site for visceral and abdominal subcutaneous adipose tissue alter associations with the metabolic syndrome?

OBJECTIVE To determine whether the associations between visceral adipose tissue (VAT), abdominal subcutaneous adipose tissue (ASAT), and the metabolic syndrome are altered depending on measurement site for VAT and ASAT and the definition used to identify the metabolic syndrome. RESEARCH DESIGN AND METHODS Total VAT and ASAT volume was derived using approximately 37 contiguous computed tomogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017