Selective Cerebral Perfusion with the Open Proximal Technique during Descending Thoracic or Thoracoabdominal Aortic Repair: An Option of Choice to Reduce Neurologic Complications.

نویسندگان

  • Katsuhiro Hosoyama
  • Shunsuke Kawamoto
  • Kiichiro Kumagai
  • Masatoshi Akiyama
  • Osamu Adachi
  • Satoshi Kawatsu
  • Yoshikatsu Saiki
چکیده

PURPOSE Selective cerebral perfusion with the open proximal technique for thoracoabdominal aortic repair has not been conclusively validated because of its procedural complexity and unreliability. We report the clinical outcomes, particularly the cerebroneurological complications, of an open proximal procedure using selective cerebral perfusion. METHODS A retrospective chart review identified 30 patients between 2007 and 2015 who underwent aortic repair through left lateral thoracotomy with selective cerebral perfusion, established through endoluminal brachiocephalic and left carotid artery and retrograde left axillary artery. RESULTS The mean durations of the open proximal procedure and cerebral ischemia (the duration of the open proximal procedure minus the duration of selective cerebral perfusion) were 110.3 ± 40.1 min and 24.8 ± 13.0 min, respectively. There were two cases (7%) of permanent neurologic dysfunction (PND) but no in-hospital deaths. Multivariate analysis identified the duration of cerebral ischemia as an independent risk factor for neurologic complications including temporary neurologic dysfunction (TND; odds ratio (OR): 1.13; p = 0.007), but no correlation was found between selective cerebral perfusion duration and neurologic complications. CONCLUSION Despite the relatively long duration of the open proximal procedure, selective cerebral perfusion has a potential to protect against cerebral complications during thoracic aortic repair through a left lateral thoracotomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repair for aneurysms of the entire descending thoracic aorta or thoracoabdominal aorta using a deep hypothermia.

OBJECTIVE Replacement of the entire descending aorta or of the thoracoabdominal aorta still has a significant risk for postoperative paraplegia. Surgical strategies using a deep hypothermia to protect the spinal cord or viscera are discussed. METHODS From April 1994, 25 patients underwent graft replacement of the entire descending aorta (13 patients) or thoracoabdominal aorta (12 patients) us...

متن کامل

A versatile extracorporeal circuit for use during repair of descending and thoracoabdominal aortic aneurysms in high-risk patients with cardiac and/or pulmonary dysfunction: a novel approach to a significant perfusion management dilemma.

The incidence of ischemic complications associated with repair of descending and thoracoabdominal aortic aneurysms has been significantly reduced by the use of distal aortic perfusion with moderate hypothermia, cerebral spinal fluid drainage, and segmental sequential clamping techniques. However, because the maintenance of proximal perfusion, the adequacy of left heart bypass (LHB), and the abi...

متن کامل

One-stage repair in complex multisegmental thoracic aneurysmal disease: results of a multicentre study.

OBJECTIVES Patients with thoracic aneurysmal disease involving the arch and the descending or thoracoabdominal aorta may require more than one surgical intervention. The results of one-stage repair using a hybrid stent-graft in the frozen elephant trunk manner are presented. METHODS Between January 2005 and March 2012, 113 (age 67 ± 10 years) of 358 registered patients in the International E-...

متن کامل

Bloody cerebrospinal fluid during replacement of descending thoracic aorta -A case report-

Cerebrospinal fluid (CSF) drainage is a routinely used adjunct to thoracoabdominal aortic surgery which may reduce the incidence of preoperative paraplegia by improving spinal cord perfusion. However, this procedure infrequently causes complications. Bloody or bloody-tinged CSF may be associated with intracranial or spinal hematoma. We present herein a case of bloody CSF during the replacement ...

متن کامل

Overall Essen's experience with the E-vita open hybrid stent graft system and evolution of the surgical technique.

BACKGROUND The hybrid stent graft prosthesis E-vita open was designed and introduced by us in 2005 to avoid a two-stage surgical approach in the surgical treatment of complex thoracic aortic disease. Experience in ascending aortic and arch replacement with simultaneous stent grafting of the descending aorta was accumulated over the past 8 years. Facilitation of surgical technique by moving the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia

دوره   شماره 

صفحات  -