Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography.
نویسندگان
چکیده
PURPOSE To assess and compare the morphology of laser in situ keratomileusis flaps (LASIK) created by a 60 kHz femtosecond laser and a mechanical microkeratome. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS Anterior segment optical coherence tomography (AS-OCT) (Visante) was used to assess 1 week postoperatively the morphology of 20 LASIK flaps created with the IntraLase femtosecond laser or the Zyoptix XP microkeratome. The flap diameter and flap thickness were assessed at 20 measuring points across each flap. First, the repeatability of the AS-OCT flap measurement was evaluated. On this basis, the dimensions of femtosecond laser flaps and microkeratome flaps were tested and their regularity, reproducibility, and accuracy compared. RESULTS The method was approved with a repeatability of maximum 8.9 mum. The femtosecond laser flaps were more regular than the microkeratome flaps (P = .02). The reproducibility of flap morphology was not different in the central 1.0 mm radius area (P = .26); however, the femtosecond laser was significantly more precise than the microkeratome in the peripheral area (P = .001). The mean thickness of the femtosecond laser flap was significantly more accurate than the mean thickness of the microkeratome flap (P = .01), with a mean deviation of +16.9 mum and 40.8 mum, respectively. CONCLUSIONS The flap architecture created with the femtosecond laser was more regular and accurate than the flap architecture created with the microkeratome.
منابع مشابه
Analysis of Thin Femtosecond Flaps with Anterior Segment Optical Coherence Tomography
Greater corneal biomechanical stability has been demonstrated following photorefractive keratectomy (PRK) compared with traditional microkeratome laser-assisted in situ keratomileusis (LASIK). Thin LASIK flaps exhibit biomechanical properties similar to PRK but with the advantage of no haze formation or pain. These findings suggest that thin flaps created with consistent thickness across the co...
متن کاملFactors Influencing Corneal Flap Thickness in Laser In Situ Keratomileusis with a Femtosecond Laser
PURPOSE To evaluate factors responsible for the variability between intended and achieved corneal-flap thickness during femtosecond laser-assisted laser in situ keratomileusis (LASIK). METHODS A prospective, nonrandomized, case study was performed on 35 eyes of 18 consecutive patients who underwent LASIK surgery using the 60 kHz femtosecond laser microkeratome. Eyes were assigned to three dif...
متن کاملComparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome.
PURPOSE To evaluate the thickness and side-cut angle of laser in situ keratomileusis (LASIK) flaps created by 1 of 3 femtosecond lasers or a microkeratome using Fourier-domain optical coherence tomography (OCT). SETTING Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea. DESIGN Comparative case series. METHODS Flap creation for b...
متن کاملTemporal and Spatial Flap Variability in Laser In-Situ Keratomileusis by Optical Coherence Tomography
PURPOSE To study changes in flap thickness made with two different microkeratome heads across different corneal locations using anterior segment optical coherence tomography (OCT). METHODS In this prospective, non-randomized, consecutive case series, subjects who had their laser in-situ keratomileusis (LASIK) flaps made using 90 μm (MSU90) or 130 μm (MSU130) disposable M2 microkeratome heads ...
متن کاملAnterior segment OCT analysis of thin IntraLase femtosecond flaps.
PURPOSE Anterior segment optical coherence tomography (OCT) was used to analyze thin flaps created with the IntraLase femtosecond laser (IntraLase Corp). METHODS Twenty-five eyes of 25 patients had flaps created with the 60 kHz IntraLase femtosecond laser prior to excimer laser ablation. The desired flap thickness was 110 microm with a diameter of 8.5 mm for all eyes. At 1 month postoperative...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 35 1 شماره
صفحات -
تاریخ انتشار 2009