Controlled comparison of BacT/ALERT FAN aerobic medium and BATEC fungal blood culture medium for detection of fungemia.

نویسندگان

  • L C McDonald
  • M P Weinstein
  • J Fune
  • S Mirrett
  • L G Reimer
  • L B Reller
چکیده

Yeasts are an increasingly common cause of nosocomial bloodstream infections. Methods for their detection are many; controlled comparisons are few. The vented FAN aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as bacteremia. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md.) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured. Therefore, we compared vented FAN to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia. From 5,109 cultures processed for which both FAN and FM bottles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with FAN only, and 28 were detected with FM only (P < 0.05). FAN was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001). A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by FAN, and 10 detected only by FM (P value, not significant). We conclude that the vented FAN aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood.

Studies have demonstrated that large-volume culture methods for sterile body fluids other than blood increase recovery compared to traditional plated-medium methods. BacT/Alert is a fully automated blood culture system for detecting bacteremia and fungemia. In this study, we compared culture in BacT/Alert standard aerobic and anaerobic bottles, BacT/Alert FAN aerobic and FAN anaerobic bottles, ...

متن کامل

Clinical comparison of nonvented aerobic BacT/Alert blood culture bottle and standard aerobic bottle for detection of microorganisms in blood.

The current BacT/Alert standard aerobic (VA) blood culture bottle was redesigned and designated a nonvented aerobic (NVA) culture bottle; this bottle does not require venting. A total of 3,873 sets of blood samples for culture were obtained from adult patients with suspected bacteremia or fungemia. The NVA bottle showed performance equivalent to that of the VA bottle for recovery and speed of d...

متن کامل

Controlled clinical comparison of the BacT/ALERT FN and the standard anaerobic SN blood culture medium.

To determine the optimal anaerobic companion bottle to pair with the BacT/ALERT (bioMerieux, Durham, N.C.) nonvented aerobic FA (FA) medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared the BacT/ALERT FN (FN) anaerobic bottle with the standard BacT/ALERT SN (SN) anaerobic bottle. Each bottle, FA, FN, and SN, was filled with 8 to 12 ml of...

متن کامل

Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

In a collaborative study at three university hospitals, the recovery of microorganisms and the speed of detection of microbial growth by the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) and BACTEC 660/730 (Becton-Dickinson Diagnostic Instrument Systems, Sparks, Md.) nonradiometric blood culture systems were compared. A total of 5,918 comparisons were made between BacT/Alert aerobic an...

متن کامل

Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instrum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2001