Misinterpretation of the Functional Severity of Coronary Stenosis Due To Variability in Arterial Wall Compliance

نویسندگان

  • Bhaskar Chandra Konala
  • Mohamed Effat
  • Arif Imran
  • Rupak K Banerjee
چکیده

Effect of arterial wall compliance on the invasive coronary diagnostic parameters for various severities of coronary stenoses was assessed. The Mooney-Rivlin model was used to define the non-linear properties of the arterial wall and the plaque regions. The nonNewtonian viscosity of blood was modeled using the Carreau model. A finite element method was employed to solve the pulsatile fluid (blood)-structure (arterial wall) interaction (FSI) equations. Variability in the diagnostic parameter values can occur near the cut-off value due to change in compliance of stenotic arteries between the range of 84% and 89% area stenosis. This may lead to misdiagnosis and might wrongly lead to postponement of coronary intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Statistical analysis of the association between rheological properties of blood and atherosclerosis

The aim of this study is to investigate the effects of non-Newtonian blood rheology models on the wall shear stress (WSS) distribution in a cohort of patients-specific coronary arteries. Twenty patients with diseased left anterior descending (LAD) coronary arteries (with varying degrees of stenosis severity from mild to severe) who underwent angiography and in-vivo pressure measurements were se...

متن کامل

Prevalence of carotid arterial diseases in patients undergoing CABG operations

 Introduction: Prevalence of stroke following coronary artery bypass graft surgery (CABG) is % 2.1-5.2 and associated with high mortality. The purpose of this study was to investigate the prevalence of carotid artery disease in patients undergoing CABG surgery.  Methods: This cross-sectional study was performed in the years 2010-2011 on 192 patients who underwent open heart surgery (CABG) in...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

The association between small dense low density lipoprotein,apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio and coronary artery stenosis

  Abstract   Background: Recently, small dense low density lipoprotein (sdLDL) has been   highlighted as a new risk factor for the coronary artery disease (CAD).Small dense   LDLs are believed to be atherogenic since these particles are taken up more easily by   arterial wall. They are readily oxidized and have reduced affinity for low density   lipoprotein (LDL) receptor and increased affinity...

متن کامل

BRIEF REVIEW Quantification of Coronary Artery Stenosis in Vivo

VISUAL interpretations of coronary arteriograms are marked by such great interobserver and intraobserver variability (Bjork et al., 1975; Detre et al., 1975; Zir et al., 1976; DeRouen et al., 1977; Meyers et al., 1978) that comparison of arteriograms from different subjects, or at different times in the same subject, are of limited value for assessing severity, changes in severity, or functiona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010