Nuclear medicine and infection detection: the relative effectiveness of imaging with 111In-oxine-, 99mTc-HMPAO-, and 99mTc-stannous fluoride colloid-labeled leukocytes and with 67Ga-citrate.

نویسنده

  • Davina K Hughes
چکیده

With a current annual mortality rate of around 35% worldwide, infection remains a significant concern, and the diagnosis and localization of infectious foci is an important health issue. As an established infection-imaging modality, nuclear medicine plays a vital health-care role in the diagnosis and subsequent effective treatment of this condition. Despite the development of several newer radiopharmaceuticals, (67)Ga and leukocyte imaging procedures have maintained their established place for infection. Several techniques in nuclear medicine significantly aid infection diagnosis, including imaging with (111)In-oxine-, (99m)Tc-hexamethylpropyleneamine oxime-, and (99m)Tc-stannous fluoride colloid-labeled leukocytes and with (67)Ga-citrate. Each radiopharmaceutical has specific advantages and disadvantages that make it suitable to diagnose different infectious processes (e.g., soft-tissue sepsis, inflammatory bowel disease, osteomyelitis, occult fever, fever of unknown origin, and infections commonly found in immunocompromised patients). After finishing this article, the reader should be able to identify the properties of an ideal radiopharmaceutical for infection imaging, list a range of available infection-imaging radiopharmaceuticals, compare the relative results of a range of radiopharmaceuticals used internationally to detect infection in the body, understand several common infectious processes that can be diagnosed using nuclear medicine techniques, and select an appropriate radiopharmaceutical to image a range of infectious processes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dichotomous Indium-111 labeled leukocyte scan findings while evaluating osteomyelitis in a failed mandibular graft

Markedly elevated111 In labeled leukocyte activity suggestive of acute osteomyelitis was observed in a region of a composite mandibular allograft that was photon deficient on 99mTc MDP bone scintigraphy. This finding was later confirmed by surgical pathology. The patient was treated with intravenous antibiotics and returned two months later with persistent bone infection. The foHow-up thr...

متن کامل

Tc-99m Labeled HMPAO white Blood Cell Scintigraphy in a patient with Hip Prosthesis

Background The ability to follow the distribution and migration of biologically active cells in human is essential for the development of cell-based therapies and diagnostics. Nuclear medicine imaging is widely applied in clinic as an attractive technique for in vivo WBC and stem cell tracking. The aim of this study was to evaluate prosthesis infection of a 51 years old man with previous histo...

متن کامل

Detection of soft-tissue infections and osteomyelitis using a technetium-99m-labeled anti-granulocyte monoclonal antibody fragment.

UNLABELLED Imaging of osteomyelitis and soft-tissue infections can be problematic with currently available agents; bone scans are often false-positive. Indium-111-oxine and 99mTc-HMPAO white blood cell (WBC) scans require ex vivo handling of blood with potential exposure to infectious agents, and 99mTc-antigranulocyte (IgG1) antibodies need 24 hr for final diagnosis. METHODS We investigated t...

متن کامل

Leukocyte labeling with technetium-99m tin colloids.

Triple density gradients of metrizamide in plasma (MP) were used to characterize label distribution in human leukocyte preparations incubated with 99mTc tin colloids. Less than 50% of the cell-associated radioactivity was specifically bound to leukocytes when heparinized blood was rotated with stannous fluoride colloid ([Tc]SFC). Labeling efficiency in leukocyte rich plasma (LRP) averaged 44%, ...

متن کامل

Nano Liposomes labeled with 99mTc-HMPAO, A Novel Agent for Blood Pool Imaging

In-vitro labeling of RBC with 99mTc is an intricate procedure and there is always a need foran alternate blood pool imaging agent. The aim of this study was to prepare an effective nanosized liposome (NLs) similar to human RBC for blood pool scintigraphy. This study formulatesPEG-NLs and non-PEG-NLs using film method plus high pressure homogenization technique.Biodistribution studies were perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2003