Cemented versus uncemented femoral components in the ring hip prosthesis.
نویسندگان
چکیده
A prospective, randomised and independently assessed trial of the Ring UPM total hip replacement showed that the quality of the early result was better if the femoral prosthesis was cemented than if it was not. More patients with cemented prostheses were painfree at four months (58% cemented:42% uncemented) and at one year (63% cemented:50% uncemented), but at two years pain relief was equal in both groups. At two years significantly more patients with cemented prostheses could walk without support (96% cemented:62% uncemented, p = 0.01 to 0.05). There is a need for more similar trials to compare the results of contemporary designs of cemented and uncemented total hip prostheses.
منابع مشابه
Mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study
BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...
متن کاملThe relative cost of cemented and uncemented total hip arthroplasties.
The use of uncemented femoral stems in primary total hip arthroplasty (THA) has been slow to develop in the UK because of the lack of encouraging published long-term follow-up data, the continued success of the cemented primary THA, and the perceived excessive relative cost of the uncemented THA. In this article, we argue that the total costs of 3 "proven" uncemented stems are comparable with c...
متن کاملCemented versus uncemented hemiarthroplasty in patients with displaced femoral neck fractures.
OBJECTIVE This study compared functional outcomes and preoperative between cemented and uncemented bipolar hemiarthroplasty in patients older than 65 years with subcapital displaced femoral neck fracture. METHODS Fifty one patients with displaced femoral neck fracture were enrolled in this study. Twenty nine patients underwent uncemented bipolar hemiarthroplasty and 22 underwent cemented bipo...
متن کاملLong-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study.
Between 1986 and 1991 we implanted 331 consecutive Furlong hydroxyapatite-coated femoral components of a total hip replacement in 291 patients. A cemented acetabular prosthesis was used in 217 hips and a hydroxyapatite-coated component in 114. We describe the long-term clinical and radiological survival of the femoral component at a mean follow-up of 17.5 years (15 to 21). Only two patients (0....
متن کاملIncreased risk of intraoperative and early postoperative periprosthetic femoral fracture with uncemented stems
Background and purpose - The use of uncemented fixation in total hip arthroplasty (THA) is increasing. Registry studies have indicated an increased risk of revision of uncemented implants due to early periprosthetic femoral fracture. In this paper, we describe the incidence and predisposing factors for intraoperative and early postoperative (≤ 90 days) periprosthetic femoral fractures after cem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 74 6 شماره
صفحات -
تاریخ انتشار 1992