BI-RADS 3, 4, and 5 lesions: value of US in management--follow-up and outcome.

نویسندگان

  • Sughra Raza
  • Sona A Chikarmane
  • Sarah S Neilsen
  • Lisa M Zorn
  • Robyn L Birdwell
چکیده

PURPOSE To evaluate the use, final outcome, and positive biopsy rate of American College of Radiology ultrasonographic (US) Breast Imaging Reporting and Data System (BI-RADS) categories 3, 4, and 5 recommended for breast masses. MATERIALS AND METHODS At US, consecutive masses, palpable and nonpalpable, categorized as BI-RADS 3, 4, and 5 between January 1, 2003, and December 31, 2004, were retrospectively reviewed with institutional review board approval. Medical records provided imaging and histologic information. RESULTS After patients lost to follow-up were excluded, the study population was 767 patients with 926 masses (476 palpable, 450 nonpalpable). In BI-RADS 3 masses (n = 356), imaging follow-up of 252 masses documented stability for 6-24 months. Aspiration of 24 masses revealed cysts. Biopsy in 80 masses revealed three malignancies, all of which were diagnosed within 6 months of the index examination, were smaller than 1 cm, and were node negative (negative predictive value = 99.2%). In BI-RADS 4 masses (n = 524), aspiration results indicated 35 cysts; biopsy in 455 revealed 85 malignancies (positive predictive value [PPV] = 16.2%). Imaging follow-up only in 34 revealed no cancers 2 and more years later. Among BI-RADS 5 masses (n = 46), 43 were malignant and three benign (PPV = 93.4%). CONCLUSION Inconsistent use of BI-RADS category 3 occurred in 14.0% of cases when biopsy was recommended. Although biopsy was performed in almost equal numbers of palpable and nonpalpable masses, only 11% of palpable BI-RADS 3 and 4 masses were malignant, as compared with 22% of nonpalpable masses. Strict adherence to lexicon characteristics of probably benign lesions should improve specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast Imaging Reporting and Data System Category 3 Lesions Detected on Whole-Breast Screening Ultrasound

PURPOSE This study assessed the incidence and cancer rate of probably benign lesions detected on bilateral whole-breast screening ultrasound (US), which corresponded to US Breast Imaging Reporting and Data System (BI-RADS) category 3, and evaluated the proper management of those lesions. METHODS This study was approved by the Institutional Review Board in our institution, which waived informe...

متن کامل

Usefulness of ultrasound elastography in reducing the number of Breast Imaging Reporting and Data System category 3 lesions on ultrasonography

PURPOSE To evaluate the negative predictive value (NPV) of ultrasound (US) elastography for non-palpable Breast Imaging Reporting and Data System (BI-RADS) category 3 lesions on ultrasonography and to determine whether US elastography is helpful in reducing the number of BI-RADS category 3 lesions on ultrasonography. METHODS Two hundred seventy-six consecutive, non-palpable BI-RADS category 3...

متن کامل

Diagnostic Performance and Additional Value of Elastosonography in Focal Breast Lesions: Statistical Correlation between Size-Dependant Strain Index Measurements, Multimodality-BI-RADS Score, and Histopathology in a Clinical Routine Setting

Objective. To evaluate the diagnostic benefit of real-time elastography (RTE) in clinical routine. Strain indices (SI) for benign and malignant tumors were assessed. Methods. 100 patients with 110 focal breast lesions were retrieved. Patients had mammography (MG), ultrasound (US), and, if necessary, MRI. RTE was conducted after ultrasound. Lesions were assessed with BI-RADS for mammography and ...

متن کامل

(BSGC) in the diagnosis of breast cancer (BC) and assessed its incremental value over mammography (Mx). A consecutive series of 467 patients underwent BSGC scintigraphy for different indi- cations: suspicious lesions on physical examination and/or on US/MRI negative at Mx

We investigated the clinical impact of breast scintigraphy acquired with a breast specific γ-camera (BSGC) in the diagnosis of breast cancer (BC) and assessed its incremental value over mammography (Mx). A consecutive series of 467 patients underwent BSGC scintigraphy for different indications: suspicious lesions on physical examination and/or on US/MRI negative at Mx (BI-RADS 1 or 3), characte...

متن کامل

Clinical Data as an Adjunct to Ultrasound Reduces the False-Negative Malignancy Rate in BI-RADS 3 Breast Lesions.

PURPOSE Ultrasound (US) is a well-established diagnostic procedure for breast examination. We investigated the malignancy rate in solid breast lesions according to their BI-RADS classification with a particular focus on false-negative BI-RADS 3 lesions. We examined whether patient history and clinical findings could provide additional information that would help determine further diagnostic ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 248 3  شماره 

صفحات  -

تاریخ انتشار 2008