Cross Strip Readout Detectors for High Time Resolution Imaging in the 120nm to 900nm Wavelength Regime

نویسندگان

  • Oswald H.W. Siegmund
  • John V. Vallerga
  • Jason McPhate
  • Barry Welsh
  • Anton Tremsin
چکیده

Detectors with cross strip anodes have been used in open face and sealed tube detectors for detection of particles and light. In combination with high resolution position encoding electronics these have the capability of being able to independently record the accurate time and position of each detected photon event. Sealed tube (18 mm) microchannel plate cross strip anode detectors with supergen-II photocathodes, and open face cross strip anode detectors up to 40mm have been commissioned. These have high spatial resolution (≤ 30 μm), are capable of high counting rates (input rates > 5 MHz), demonstrate time tagging of events with ~1.5 ns accuracy, and provide extended lifetimes. Related developments of high efficiency GaN photocathodes and novel MCP structures capable of providing 20 x 20 cm devices potentially enhance the applicability of these devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Spatial resolution GaN and Optical Photon Counting Detectors with sub-nanosecond timing for Astronomical and Space Sensing Applications

Recent advances in UV-Visible ground and space borne detectors with the unique ability to record photon X,Y,T high fidelity information include the development of GaN UV photocathodes and cross strip high resolution position encoding readouts. Such sensors have the distinct advantage of being able to record the accurate time of each detected photon event, which is important for time dependent a...

متن کامل

Spatial Resolution and Imaging of Gamma-Rays with Germanium Strip Detectors

Germanium strip detectors combine high quality spectral resolution with two-dimensional positioning of -ray interactions. Readout is accomplished using crossed electrodes on opposite faces of a planar germaniumdetector. Potential astrophysics applications include focal plane detectors for coded-aperture or grazing incidence X-ray mirror imagers, and as detection elements of a high resolution Co...

متن کامل

A silicon strip detector system for high resolution particle tracking in turbulence

We describe a high speed imaging system that is used to track tracer particles in highly turbulent flows. The system uses silicon strip detectors designed for high energy physics experiments and is capable of reading two detectors at a frame rate of 70 kHz. Each detector contains 512 strips and measures a one-dimensional projection of the light striking it. The position measurements from this s...

متن کامل

Microchannel plate cross-strip detectors with high spatial and temporal resolution.

The cross-strip imaging readout employs charge division, and centroiding, of microchannel plate charge signals detected on two orthogonal layers of sense strips to encode event X-Y positions and times. We have developed cross-strip detectors and fully parallel channel position encoding electronics. The front-end amplifiers utilize two 32-channel pre-amplifier ASICs that send signals to a full 6...

متن کامل

Cross Strip Anode Imaging Readouts for Microchannel Plate Detectors

We have developed a novel microchannel plate readout scheme, the cross strip anode. The cross strip anode has a coarse (0.5mm) multilayer metal and ceramic cross strip pattern that encodes event positions by direct sensing of the charge on each strip and subsequent determination of the charge cloud centroid for each event. Event position encoding is accomplished with chip level preamplifiers on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010