Beam test results of CMS RPCs at high eta region under high-radiation environment
نویسندگان
چکیده
The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz=cm. It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50Hz=cm, compared to only 5Hz=cm for the oiled RPC, both at 10:0kV which is about 100V above the 95% knee of the efficiency curve. r 2004 Elsevier B.V. All rights reserved.
منابع مشابه
Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC
Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitabl...
متن کاملRadiation experience with the CMS pixel detector
The CMS pixel detector is the innermost component of the CMS tracker occupying the region around the centre of CMS, where the LHC beams are crossed, between 4.3 cm and 30 cm in radius and 46.5 cm along the beam axis. It operates in a high-occupancy and high-radiation environment created by particle collisions. Studies of radiation damage effects to the sensors were performed throughout the firs...
متن کاملThe bakelite for the RPCs of the experiment CMS
Results from aging tests on the bakelite used for the CMS RPCs are presented. Samples of melaminic bakelite were exposed to a heavy gamma and neutron radiation. Data on the bulk resistivity were collected while accumulating gamma and neutron doses and particles #uence up to values well beyond those expected in 10 years of RPCs operation in the barrel region of CMS. The test with gamma radiation...
متن کاملNeutron irradiation of RPCs for the CMS experiment
All the CMS muon stations will be equipped with Resistive Plate Chambers (RPCs). They will be exposed to high neutron background environment during the LHC running. In order to verify the safe operation of these detectors, an irradiation test has been carried out with two RPCs at high neutron flux (about 10 n cm 2 s ), integrating values of dose and fluence equivalent to 10 LHC-years. Before an...
متن کاملMeasurements of Lead Tungstate crystals behaviour under irradiation for the CMS electromagnetic calorimeter at the LHC
Lead Tungstate crystals will be used as calorimetric medium in high energy physics at CERN, in a particularly hostile radiation environment. Methods of testing their behaviour under irradiation are discussed here and are illustrated by some R&D results. Presented at 5th European Conference on Radiation and its Effects on Components and Systems, (Fontevraud, France, September 1999) For the CMS C...
متن کامل