Patient-prosthesis mismatch after transapical aortic valve implantation.
نویسندگان
چکیده
OBJECTIVES Transcatheter aortic valve implantation (TAVI) has become an important therapeutic option for high-risk patients with severe aortic valve stenosis. Patient-prosthesis mismatch (P-PM) is an important determinant of morbidity and mortality after open aortic valve replacement. The objective of our study was to evaluate P-PM incidence and its impact on survival in a large cohort of patients treated with TAVI. METHODS AND RESULTS We retrospectively analyzed transesophageal echocardiographic data of 278 consecutive patients (Society of Thoracic Surgeons score 18.5 ± 15.3, age 80 ± 8 years) who underwent transapical TAVI with Edwards Sapien valves between April 2008 and March 2011. Effective orifice area was calculated using the continuity equation and indexed with body surface area (iEOA). P-PM was stratified as severe (iEOA < 0.65 cm(2)/cm(2)) and moderate (iEOA, 0.65-0.85 cm(2)/m(2)). Midterm survival (up to 30 months) was analyzed by Kaplan-Meier curves and log-rank tests. There was no P-PM in 181 (65.1%) patients; moderate P-PM was found in 76 (27.3%) patients and severe P-PM in 21 (7.6%). Thirty-day survival was 96.0%, 97.3%, and 90.5%. The 3-month survival was 91%, 90%, and 66%, respectively (P = .0013). Combination of severe P-PM with peak pressure gradients greater than 10 mm Hg further reduced the 3-month survival to 48%. Additionally, mean survival time in patients with an ejection fraction less than 50% was significantly shorter than in patients with an ejection fraction greater than 50% (20.8 ± 1.5 vs 24.1 ± 0.8 months; P = .027). CONCLUSIONS P-PM is found in patients undergoing transapical TAVI. Severe mismatch is accompanied by high early mortality, especially when combined with increased pressure gradients.
منابع مشابه
Subacute left ventricular outflow tract obstruction after transapical closure of a mitral paravalvular leak in the region of the aortomitral curtain.
We report a rare case of progressive left ventricular outflow tract (LVOT) obstruction after percutaneous device closure of a mechanical prosthetic mitral valve (MV) paravalvular leak (PVL) in the region of aortomitral curtain in a patient who also had small mechanical aortic valve prosthesis with patient-prosthesis mismatch.
متن کاملTransapical aortic valve implantation in a patient with increased diameter of the aortic annulus and extensive calcification
Methods The patient is a 66y old male referred for evaluation of aortic stenosis, and presenting with fatigue, class III heart failure, hypertension, diabetes, 1st degree AV block, LBBB, previous stroke and moderate CKD. EuroSCORE I was 5.35% and EuroSCORE II was 1.98%. Echocardiography confirmed severe aortic stenosis, with an annulus 0.8 cm2, mean and peak systolic gradient 54 and 86 mmHg, an...
متن کاملImage-Guided Transcatheter Aortic Valve Implantation Assistance System
Transcatheter aortic valve implantation (TAVI) is a recently developed surgical technique to treat symptomatic aortic valve stenosis in elderly and high-risk patients (Eltchaninoff et al., 2008; Ferrari & von Segesser, 2010). Compared to the standard aortic valve replacement surgery, the TAVI limits the surgical access to either a small minithoracotomy (transapical TAVI) or femoral approach (tr...
متن کاملSuccessful transapical aortic valve replacement in a patient with a previous mechanical mitral valve replacement.
In this case we illustrate our experience with transapical minimal invasive aortic valve replacement in a patient who previously underwent mitral valve replacement. The implantation did not interfere with the existing prosthesis and could even be used as a further landmark, helping height positioning of the aortic valve.
متن کاملSeventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?
BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...