Purification of tryptic peptides for mass spectrometry using polyvinylidene fluoride membrane.
نویسندگان
چکیده
A simple procedure for the purification of tryptic peptides, prior to mass spectrometric analysis, using polyvinylidene fluoride membrane (PVDF) is described. The sensitivity of mass spectrometric analysis is such that minor impurities in tryptic peptide digests suppress the signal obtained. However, we obtained useful signal, from a sample that did not yield any spectra earlier, by purifying the sample using PVDF membrane. For this, the tryptic peptide digest was first spotted on the membrane which was then air-dried and washed. Further, the membrane was extracted with trifluoroacetic acid (TFA) and acetonitrile and subjected to mass spectrometric analysis. This procedure enabled us to identify a cross-reactive D1 antigen on the neutrophil surface that bound antibodies that targeted 60 kD Ro autoantigen in systemic lupus erythematosus, an autoimmune disorder.
منابع مشابه
Rapid Identification of Protein Phosphatase 1-binding Proteins by Mixed Peptide Sequencing and Data Base Searching CHARACTERIZATION OF A NOVEL HOLOENZYMIC FORM OF PROTEIN PHOSPHATASE
Microcystin-affinity chromatography was used to purify 15 protein phosphatase 1 (PP1)-binding proteins from the myofibrillar fraction of rabbit skeletal muscle. To reduce the time and amount of material required to identify these proteins, proteome analysis by mixed peptide sequencing was developed. Proteins are resolved by SDS-polyacrylamide gel electrophoresis, electroblotted to polyvinyliden...
متن کاملRapid identification of protein phosphatase 1-binding proteins by mixed peptide sequencing and data base searching. Characterization of a novel holoenzymic form of protein phosphatase 1.
Microcystin-affinity chromatography was used to purify 15 protein phosphatase 1 (PP1)-binding proteins from the myofibrillar fraction of rabbit skeletal muscle. To reduce the time and amount of material required to identify these proteins, proteome analysis by mixed peptide sequencing was developed. Proteins are resolved by SDS-polyacrylamide gel electrophoresis, electroblotted to polyvinyliden...
متن کاملHigh-throughput method for N-terminal sequencing of proteins by MALDI mass spectrometry.
A high-throughput method for sequencing of N termini of proteins by using postsource decay (PSD) of matrix-assisted laser desorption/ionization mass spectrometry has been developed. After a protein blotted on the PVDF membrane was successively reduced, S-alkylated, and guanidinated, its N-amino group was coupled to biotinylcysteic acid. The protein was then extracted from the membrane and diges...
متن کاملEfficient Immobilised TiO2 in Polyvinylidene fluoride (PVDF) Membrane for Photocatalytic Degradation of Methylene Blue
Immobilised titanium dioxide (TiO2) in membrane structures has recently become attractive. This is due to the elimination of the separation step after the process of photocatalytic degradation. The efficiency of the TiO2 surface area exposed to UV light as the main important parameter needs to be considered. The immobilisation of TiO2 nanoparticles in the polyvinylidene fluoride (PVDF) membrane...
متن کاملPolyvinylidene Fluoride Hollow Fiber Membrane Contactor Incorporating Surface Modifying Macromolecule for Carbon Dioxide Stripping from Water
Porous surface modified polyvinylidene ïuoride (PVDF) hollow fiber membranes are fabricated through a dry-wet phased inversion process. Surface modifying macromolecules (SMM) (1 wt. %) are used as additives in the spinning dope. The performance of the surface modified membrane in contactor application for CO2 stripping from water is assessed through the fabricated gas–liquid membrane contacto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Indian journal of biochemistry & biophysics
دوره 38 4 شماره
صفحات -
تاریخ انتشار 2001