Compressive fatigue properties of a commercially available acrylic bone cement for vertebroplasty.
نویسندگان
چکیده
Acrylic bone cements are widely used for fixation of joint prostheses as well as for vertebral body augmentation procedures of vertebroplasty and balloon kyphoplasty, with the cement zone(s) being subjected to repeated mechanical loading in each of these applications. Although, in vertebroplasty and balloon kyphoplasty, the cement zone is exposed to mainly cyclical compressive load, the compressive fatigue properties of acrylic bone cements used in these procedures are yet to be determined. The purposes of the present study were to determine the compressive fatigue properties of a commercially available cement brand used in vertebroplasty, including the effect of frequency on these properties; to identify the cement failure modes under compressive cyclical load; and to introduce a screening method that may be used to shorten the lengthy character of the standardized fatigue tests. Osteopal[Formula: see text] was used as the model cement in this study. The combinations of maximum stress and frequency used were 50.0, 55.0, 60.0, 62.5 and 75.5 MPa at 2 Hz; and of 40.0, 55.0, 60.0, 62.5 or 75.5 MPa at 10 Hz. Through analysis of nominal strain-number of loading cycles results, three cement failure modes were identified. The estimated mean fatigue limit at 2 Hz (55.4 MPa) was significantly higher than that at 10 Hz (41.1 MPa). The estimated fatigue limit at 2 Hz is much higher than stresses commonly found in the spine and also higher than that for other acrylic bone cements tested in a full tension-compression fatigue test, which indicates that tension-compression fatigue testing may substantially underestimate the performance of cements intended for vertebroplasty. A screening method was introduced which may be used to shorten the time spent in performing compressive fatigue tests on specimens of acrylic bone cement for use in vertebral body augmentation procedures.
منابع مشابه
The effect of oligo(trimethylene carbonate) addition on the stiffness of acrylic bone cement
With the increasing elderly population an increase in the number of bony fractures associated to age-related diseases such as osteoporosis also follows. The relatively high stiffness of the acrylic bone cements used in these patients has been suggested to give raise to a suboptimal load distribution surrounding the cement in vivo, and hence contribute to clinical complications, such as addition...
متن کاملInjectable acrylic bone cements for vertebroplasty with improved properties.
Currently commercially available acrylic bone cements lack adequate radiopacity and viscosity when they are used in percutaneous vertebroplasty (PVP). In this work improved formulations of radiopaque and injectable poly(methyl methacrylate) bone cements were prepared with different amounts (10-50 wt.%) of BaTiO3 or SrTiO3 particles as the radiopaque agent. Two sets of cements were prepared by u...
متن کاملMechanical Properties and Cytocompatibility Improvement of Vertebroplasty PMMA Bone Cements by Incorporating Mineralized Collagen
Polymethyl methacrylate (PMMA) bone cement is a commonly used bone adhesive and filling material in percutaneous vertebroplasty and percutaneous kyphoplasty surgeries. However, PMMA bone cements have been reported to cause some severe complications, such as secondary fracture of adjacent vertebral bodies, and loosening or even dislodgement of the set PMMA bone cement, due to the over-high elast...
متن کاملMechanical Properties of Acrylic Bone Cement Containing the New Soluble Contrast Medium - Iohexol Hexaacetate
INTRODUCTION Acrylic bone cements, used in arthroplasty, incorporates contrast media to make them radiopaque and visible on X-ray images. However, today’s particulate contrast media cause three disadvantages to the acrylic bone cement, namely; third body wear, decreased mechanical properties and reduced biocompatibility. Iohexol hexaacetate (IHA) is a new iodide based non-ionic contrast medium,...
متن کاملBiocompatibility of alendronate-loaded acrylic cement for vertebroplasty.
This paper reports a biological evaluation of a non-resorbable acrylic cement loaded with alendronate for the treatment of osteoporotic vertebral compression fractures. The cement formulation was based on polymethyl methacrylate and acrylic monomers; one of these had covalently linked vitamin E residues. The same cement in the absence of alendronate was used as a control. The setting of the cha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomechanics and modeling in mechanobiology
دوره 13 6 شماره
صفحات -
تاریخ انتشار 2014