LAAS Sigma-Mean Monitor Analysis and Failure-Test Verification
نویسندگان
چکیده
The Local Area Augmentation System (LAAS) is a ground-based differential GPS system being developed to support aircraft precision approach and landing navigation with guaranteed integrity. Stanford University has designed, implemented and tested a LAAS ground Facility (LGF) prototype, known as the Integrity Monitor Testbed (IMT), which is used to insure that the LGF meets its requirements for navigation integrity. One significant integrity risk is that the mean of the pseudorange correction error distribution becomes nonzero or that its standard deviation (sigma) grows to exceed the broadcast correction error sigma (σpr_gnd) during LAAS operation. Real-time mean and sigma monitoring is necessary to help insure that the true error distribution is bounded by a zero-mean Gaussian distribution with the broadcast sigma value. In addition to ensuring that the error distribution based on the broadcast sigmas overbounds the true error distribution under nominal conditions, mean and sigma monitoring is needed to detect violations due to unexpected anomalies with acceptable residual integrity risk. Both mean/sigma estimation and Cumulative Sum (CUSUM) methods are useful in this respect. For sigma monitoring, estimation more rapidly detects small violations of σpr_gnd, but the fast-impulse-response (FIR) CUSUM variant more promptly detects significant violations that would pose a larger threat to user integrity. Based on these analytical results, mean and sigma estimation and CUSUM methods have been implemented in the IMT and have been tested under both nominal and failure conditions. Under nominal conditions, both sigma estimates and CUSUMs stay below the relevant detection thresholds for all visible satellites in the IMT datasets we have tested. In failure testing, both sigma estimation and CUSUM methods reliably detect injected sigma violations, although both methods are limited by the 200second interval between independent B-values. Similar results were obtained in testing of the mean monitors. Overall, both methods work smoothly and predictably for sigma and mean monitoring to maintain user integrity under both nominal and failure conditions.
منابع مشابه
Sigma Estimation, Inflation, and Monitoring In the LAAS Ground System
The prescribed Local Area Augmentation System (LAAS) algorithms for the generation of vertical and horizontal protection levels implicitly assume a zero-mean, normally distributed fault-free error model for the broadcast pseudorange corrections. While such a model appears to be consistent with reference receiver ranging errors due to thermal noise and diffuse multipath, remaining errors such as...
متن کاملCUSUM-Based Real-Time Risk Metrics for Augmented GPS and GNSS
Sigma monitoring is a key component of the real-time integrity verification capability demonstrated by the Stanford University Local Area Augmentation System (LAAS) Ground Facility prototype known as the Integrity Monitor Testbed (IMT). The IMT has both sigma estimation and sigma Cumulative Sum (CUSUM) algorithms to detect small and large sigma violations, respectively. When combined with a pri...
متن کاملThe Impact of Measurement Biases on Availability for CAT III LAAS
The original error description for the Local Area Augmentation System (LAAS) assumed unbiased measurement errors. In practice, however, satellite ranging errors may exhibit nonzero means. The LAAS error bound must account for these biases. This requirement places a particularly stringent demand on Category III (CAT III) LAAS, a future LAAS variant that will enable safe automated landing through...
متن کاملEfficacy of fuzzy MADM approach in Six Sigma analysis phase in automotive sector
Six Sigma is a strategy for achieving process improvement and operational excellence within an organization. Decisions on critical parameter selection in analysis phase are always very crucial; it plays a primary role in successful execution of Six Sigma project and for productivity improvement in manufacturing environment and involves the imprecise, vague and uncertain information. Using a cas...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کامل