Sudden Death in Patients With Cardiac Implantable Electronic Devices.
نویسندگان
چکیده
IMPORTANCE Interrogations and autopsies of sudden deaths with cardiac implantable electronic devices (CIEDs) are rarely performed. Therefore, causes of sudden deaths with these devices and the incidence of device failure are unknown. OBJECTIVE To determine causes of death in individuals with CIEDs in a prospective autopsy study of all sudden deaths over 35 months as part of the San Francisco, California, Postmortem Systematic Investigation of Sudden Cardiac Death (POST SCD) study. DESIGN, SETTING, AND PARTICIPANTS Full autopsy, toxicology, histology, and device interrogation were performed on incident sudden cardiac deaths with pacemakers or implantable cardioverter defibrillators (ICDs). The setting was the Office of the Chief Medical Examiner, City and County of San Francisco. Participants included all sudden deaths captured through active surveillance of all deaths reported to the medical examiner and San Francisco residents with an ICD (January 1, 2011, to November 30, 2013). MAIN OUTCOMES AND MEASURES Identification of a device concern in sudden deaths with CIEDs, including hardware failures, device algorithm issues, device programming issues, and improper device selection. For the ICD population, outcomes were the cumulative incidence of death and sudden cardiac death and the proportion of deaths with an ICD concern. RESULTS Twenty-two of 517 sudden deaths (4.3%) had CIEDs, and autopsy revealed a noncardiac cause of death in 6. Six of 14 pacemaker sudden deaths and 7 of 8 ICD sudden deaths died of ventricular tachycardia or ventricular fibrillation. Device concerns were identified in half (4 pacemakers and 7 ICDs), including 3 hardware failures contributing directly to death (1 rapid battery depletion with a sudden drop in pacing output and 2 lead fractures), 5 ICDs with ventricular fibrillation undersensing, 1 ICD with ventricular tachycardia missed due to programming, 1 improper device selection, and a pacemaker-dependent patient with pneumonia and concern about lead fracture. Of 712 San Francisco residents with an ICD during the study period, 109 died (15.3% cumulative 35-month incidence of death), and the 7 ICD concerns represent 6.4% of all ICD deaths. CONCLUSIONS AND RELEVANCE Systematic interrogation and autopsy of sudden deaths in one city identified concerns about CIED function that might otherwise not have been observed. Current passive surveillance efforts may underestimate device malfunction. These methods can provide unbiased data regarding causes of sudden death in individuals with CIEDs and improve surveillance for CIED problems.
منابع مشابه
Leadless Pacemakers: practice and promise in congenital heart disease
The development of the implantable cardiac pacemaker nearly 60 years ago represented a paradigm shift in the control of potentially lethal heart rhythms and has revolutionized the lives of those at risk of sudden death from bradycardia. Subsequent technological developments have resulted in devices that offer additional benefits to patients, including defibrillation and resychronisation therapy...
متن کاملImplantable Cardiac Devices
Electrical cardiac pacing for the management of bradyarrhythmias was first described in 1952, and permanent transvenous pacing devices were introduced into clinical practice in the early 1960s. The first devices for endocardial defibrillation were implanted in surviving victims of sudden cardiac death in 1980. Implanted electrical devices for the management of cardiac dysrhythmias have changed ...
متن کاملSubcutaneous implantable cardioverter-defibrillator placement in a patient with a preexisting transvenous implantable cardioverter-defibrillator
Introduction The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a safe and effective treatment for prevention of sudden cardiac death. It is typically not used in patients who require additional therapies conferred by transvenous implantable cardioverter-defibrillator (TV-ICD) systems, such as bradycardia pacing or antitachycardia pacing (ATP) for ventricular tachycardia (VT). D...
متن کاملNew horizon for infection prevention technology and implantable device
There has been a significant increase in the number of patients receiving cardiovascular implantable electronic devices (CIED) over the last two decades. CIED infection represents a serious complication after CIED implantation and is associated with significant morbidity and mortality. Recently, newly advanced technologies have offered attractive and suitable therapeutic alternatives. Notably, ...
متن کاملCardiac Arrhythmia 3 Ventricular arrhythmias and sudden cardiac death
Management strategies for ventricular arrhythmias are guided by the risk of sudden death and severity of symptoms. Patients with a substantial risk of sudden death usually need an implantable cardioverter defibrillator (ICD). Although ICDs effectively end most episodes of ventricular tachycardia or ventricular fibrillation and decrease mortality in specific populations of patients, they have in...
متن کاملManagement of the patient with an implantable cardioverter-defibrillator in the third millennium.
Implantable cardioverter-defibrillator (ICD) devices were originally developed for prevention of sudden cardiac death (SCD). They are now widely regarded as the primary therapy for this condition. Clinical trials have led to a progressive expansion in indications for their use.1,2 Recent clinical reports show effectiveness of these devices in patients with recurrent syncope, in the prevention o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA internal medicine
دوره 175 8 شماره
صفحات -
تاریخ انتشار 2015