False-positive acetaminophen results in a hyperbilirubinemic patient.

نویسندگان

  • Roger L Bertholf
  • Laura M Johannsen
  • Alireza Bazooband
  • Vafa Mansouri
چکیده

BACKGROUND Acetaminophen was falsely detected in the plasma of a severely jaundiced patient, and a methodologic interference from bilirubin was suspected. METHODS Acetaminophen was measured by an enzymatic method (GDS Diagnostics). The putative bilirubin interference was investigated in 12 hyperbilirubinemic specimens and in bilirubin linearity calibrators. The analytical method was modified to correct for background absorbance at a second wavelength. Hyperbilirubinemic specimens were fortified with acetaminophen to assess the effect of the interference on acetaminophen measurements. RESULTS Acetaminophen was detected in 12 specimens from hyperbilirubinemic patients without a history of recent acetaminophen exposure. Dilution of hyperbilirubinemic specimens produced a nonproportional decrease in apparent acetaminophen concentrations, and no acetaminophen was detected when bilirubin was <50 mg/L. Background correction at a second wavelength failed to compensate for the interference. Although erroneous acetaminophen concentrations were detected in all specimens with high bilirubin, acetaminophen measurements in fortified specimens were accurate. CONCLUSION The data are consistent with bilirubin interference in the enzymatic and/or chromogenic reactions involved in the acetaminophen method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

False positive acetaminophen concentrations in icteric serum

INTRODUCTION Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. DESCRIPTION A 49-year-old wom...

متن کامل

False Negative Fecal Occult Blood Test: Prozone Effect

Dear editor, the fecal occult blood test is the presently widely used screening laboratory test for colorectal cancer. At present, the test is usually based on an immunological diagnostic principle (1, 2). A false positive fecal occult blood is common and widely mentioned in literature. Nevertheless, the false negative is little mentioned in the paper. Here, the authors discuss the issue of the...

متن کامل

Multiple non-malignant iodine uptake in a 131I whole body scan of a patient with papillary thyroid carcinoma: Importance of SPECT/CT

After thyroidectomy in papillary thyroid carcinoma (PTC) patients, whole body radioiodine scan (WBIS) is necessary for localization of any abnormal radioiodine avid lesions. However false-positive radioiodine uptake in WBIS can be problematic. We report a 32 years old female patient with PTC. After thyroidectomy and radioiodine therapy WBIS was performed. In her post therapy WBIS, there were zo...

متن کامل

False positive 18F-FDG PET/CT due to active varicella zoster infection in a Hodgkin’s lymphoma patient

We report a case of Hodgkin lymphoma (classic type) referred for response assessment after two cycles of chemotherapy with ABVD regiment. The F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET/CT) showed hypermetabolic cutaneous and subcutaneous lesions with a linear pattern in the left arm with significant F-18 fluorodeoxyglucose positron accumulation in associate with left axi...

متن کامل

HIV false positive results and Flu vaccination

Abstract False positive results are the major problem influencing interpretation of Clinical Laboratory test. They are originated mostly in the other diseases, technical errors and the recent vaccination. The problem has been presented since 1991 is positive HIV test after influenza Vaccination (1). The False positive has been reported in Cases using Eliza, one of The most common test to screen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 49 4  شماره 

صفحات  -

تاریخ انتشار 2003