Tantalum oxide honeycomb architectures for the development of a non-enzymatic glucose sensor with wide detection range.
نویسندگان
چکیده
Tantalum oxide honeycomb nanostructures (THNS) were fabricated by electrochemical anodisation of tantalum in H2SO4-HF medium. XRD analysis showed that annealing of THNS at 400 °C improves the crystallinity. HRSEM and AFM results illustrated that nanopores with an average diameter of 30 nm were uniformly distributed and the pore size reduced to 24 nm and 18 nm during subsequent electrodeposition of Pt and CuO. Electrodeposited Pt and CuO exhibited face centered cubic (fcc) and monoclinic crystal structure respectively. Cyclic voltammetric studies revealed that, on the hybrid material electrooxidation of glucose occurs at a lower potential (0.45 V). The sensor exhibited linear response to glucose up to 31 mM, fast response time (<3 s) and a low detection limit of 1 μM (S/N=3). The sensor is free of interference from ascorbic acid, uric acid, dopamine and acetaminophen. Sensor was used to analyze glucose in blood serum samples.
منابع مشابه
Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملCuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry (DPV) and Other Voltammetry Methods and Comparing to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution
A cuprous oxide (Cu2O) thin layer served as the base for a non-enzymatic glucose sensor in an alkaline medium, 0.1 NaOH solution, with a linear range of 50-200 mg/dL using differential pulse voltammetry (DPV) measurement. An X-ray photoelectron spectroscopy (XPS) study confirmed the formation of the cuprous oxide layer on the thin gold film sensor prototype. Quantitative detection of glucose in...
متن کاملNon-Enzymatic Glucose Sensing Using Carbon Quantum Dots Decorated with Copper Oxide Nanoparticles
Perturbations in glucose homeostasis is critical for human health, as hyperglycemia (defining diabetes) leads to premature death caused by macrovascular and microvascular complications. However, the simple and accurate detection of glucose in the blood at low cost remains a challenging task, although it is of great importance for the diagnosis and therapy of diabetic patients. In this work, car...
متن کاملA Cuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry and Other Voltammetry Methods and a Comparison to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution
A cuprous oxide (Cu₂O) thin layer served as the base for a non-enzymatic glucose sensor in an alkaline medium, 0.1 NaOH solution, with a linear range of 50-200 mg/dL using differential pulse voltammetry (DPV) measurement. An X-ray photoelectron spectroscopy (XPS) study confirmed the formation of the cuprous oxide layer on the thin gold film sensor prototype. Quantitative detection of glucose in...
متن کاملNon-Enzymatic Glucose Sensor Composed of Carbon-Coated Nano-Zinc Oxide
Nowadays glucose detection is of great importance in the fields of biological, environmental, and clinical analyzes. In this research, we report a zinc oxide (ZnO) nanorod powder surface-coated with carbon material for non-enzymatic glucose sensor applications through a hydrothermal process and chemical vapor deposition method. A series of tests, including crystallinity analysis, microstructure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 50 شماره
صفحات -
تاریخ انتشار 2013