Long-term trends in radiation damage of Chandra X-ray CCDs
نویسنده
چکیده
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth’s radiation belts. Current operations require ACIS to be protected during radiation belt passages to prevent this type of damage, but there remains a much slower and more gradual increase. We present the history of ACIS charge transfer inefficiency (CTI), and other measures of radiation damage, from January 2000 through June 2005. The rate of CTI increase is low, of order 10 per year, with no indication of step-function increases due to specific solar events. Based on the time history and CCD location of the CTI increase, we speculate on the nature of the damaging particles.
منابع مشابه
ar X iv : a st ro - p h / 06 06 17 8 v 1 7 J un 2 00 6 Temperature dependence of charge transfer inefficiency in Chandra X - ray CCDs
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of mag...
متن کاملAdvanced CCD imaging spectrometer (ACIS) instrument on the Chandra X-ray Observatory
The ACIS instrument has been operating for three years in orbit, producing high quality scientific data on a wide variety of X-ray emitting astronomical objects. Except for a brief period at the very beginning of the mission when the CCDs were exposed to the radiation environment of the Outer van Allen Belts which resulted in substantial radiation damage to the front illuminated CCDs, the instr...
متن کاملA Technique to Measure Trap Characteristics in CCDs Using X-rays
An important type of radiation damage in CCDs used for X-ray spectroscopy is the degradation of charge transfer eeciency (CTE). Traps associated with radiation induced defects are the basic cause of the damage. Here, we describe a method to extract trap characteristics using small charge packets produced by individual X-ray photon interactions in rectangular imaging CCDs. The method applies the...
متن کاملThe Temporal Characteristics of the Chandra X-ray Observatory High Energy Particle Background
It was observed early on in the Chandra X-ray Observatory mission that the background rates of the Advanced CCD Imaging Spectrometer (ACIS) were highly variable on both short and long timescales. We present analysis of lightcurves of the high energy (> 15 keV) ACIS background spanning most of the mission lifetime. These high energy events are not produced by astrophysical X-rays, but by the par...
متن کاملar X iv : a st ro - p h / 04 07 19 9 v 1 9 J ul 2 00 4 A charge transfer inefficiency correction model for the Chandra Advanced CCD Imaging Spectrometer
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of mag...