The importance of CT imaging for detecting traumatic intraorbitar and maxillofacial foreign bodies

نویسندگان

  • Roxana Popescu
  • B. Dobrovăţ
  • A. Nemţoi
  • Oana Lăduncă
  • Danisia Haba
چکیده

The study represents an evaluation of the ability of spiral and conventional computer tomography in the diagnoseof intraorbitar and intraocular foreign bodies. The study includes 19 patients, aged between 15 and 52 years, 10 men and 9 women, presenting intraocular or intraorbitar foreign bodies or as a result of an traumatic injuries, who addressed the Emergency Hospital N. Oblu Iasi, between September 2010 March 2011. The CT examination was the main imaging method of investigation in addition to conventional radiographs; it was conducted on a Philips Aura single-slice unit and a Siemens SOMATOM AR.C unit in the Department of Radiology and Medical Imaging in theHospital “N. Oblu” Iasi. One patient presents an CT image of carbonite IOFB, 5 patients present metallic IOFB, the images are obtained using used incremental CT (Somatom ARC, Siemens). 2 patients present spiral CT image of a metallic penetrating intraocular foreign body, 11 patients present spiral CT image of a metallic penetrating intraocular and maxillofacial foreign body. The classical computer tomography and spiral CT are among the most effective methods of examination and management of intraocular foreign bodies, maxillofacial or intraorbital. The spiral CT realise a continuous scanning of a volume of the patients body during table movement and reduces examination time and radiation exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Foreign Bodies by Spiral Computed Tomography and Cone Beam Computed Tomography in Maxillofacial Regions

Background and aims. The imaging techniques commonly used for foreign body detection include plain radiography, xeroradiography, computed tomography (CT) scans, magnetic resonance imaging (MRI) and ultrasonography. The aim of the present study was to compare cone-beam computed tomography (CBCT) with conventional CT scan in determination of the exact location of a foreign body in the maxillofaci...

متن کامل

Comparative Sensitivity Assessment of Cone Beam Computed Tomography and Digital Radiography for detecting Foreign Bodies.

AIM Foreign body detection and determining whether it is adjacent to critical organs has a significant role in its removal. Various imaging techniques have been used to locate foreign bodies. This study aimed to compare cone beam computed tomography (CBCT) and digital radiography for detecting foreign bodies in an in vitro model. MATERIALS AND METHODS Foreign bodies composed of normal glass, ...

متن کامل

Comparison between Computed Tomography and Ultrasonography in Detecting Foreign Bodies Regarding Their Composition and Depth: An In Vitro Study

STATEMENT OF THE PROBLEM Impaction of foreign bodies in the soft tissues is a sequela of traumatic and penetrating injuries. Such foreign bodies should be removed due to the complications they cause. Patient's history, clinical evaluation and imaging examinations aid in the proper detection and localization of the foreign bodies. PURPOSE The aim of the present study was to compare the sensiti...

متن کامل

در ارزیابی سرطان سلول MRI و CT-Scan مقایسه (SCC) سنگفرشی حفره دهان

Background and purpose: Squamous Cell Carcinoma (SCC) is the most common head and neck malignancy. To decrease the side effects of treatment and the rate of mortality, careful staging for proper treatment plan is necessary. The purpose of this prospective study was to compare the diagnostic value of two different imaging methods (Computed Tomography (CT) and Magnetic Resonance Imaging (MRI)...

متن کامل

CT evaluation of plastic intraocular foreign bodies.

The high sensitivity of CT in detecting metallic orbital foreign bodies has been previously described [1-6] . While there has been some success in detecting glass fragments , detecting intraorbital foreign bodies made of wood has been very unsatisfactory [1, 2, 69]. Plastic orbital implants are easily recognized on CT as high-attenuation-value images [6, 7]. This report presents two cases of pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011