CT-Compatible Medical Drilling Stylet
نویسندگان
چکیده
This paper describes the design of a compact, lightweight CT-compatible, drill-press that is designed to be used in either a hand-held or stand-alone mode to assist with percutaneous bone based interventions. Previous medical drilling tools that have been developed have a metal structure and typically have one actuator for advancing the drill (feed) and another for rotating it (speed). After defining the device functional requirements and specifications, a deterministic design process was followed to generate several design concepts that were then evaluated based on their ability to satisfy the functional requirements. A final concept that uses a custom screw-spline to achieve helical motion of a shaft that is attached to a standard orthopedic drill was selected for prototyping. The design uses a single actuator to drive both the screw and spline nuts through two different gear ratios, resulting in a fixed ratio between the feed and speed. Apart from the motor which is placed away from the central drill axis, the device is largely made from plastic materials. A custom experimental setup was developed that enabled drilling into bone inside a CT scanner to be examined. Results showed that the device was successfully able to penetrate thick cortical bone and that its structure did not appreciably distort the medical images. [DOI: 10.1115/1.4007280]
منابع مشابه
Active Needle Steering System for Percutaneous Prostate Intervention in High-field MRI
This paper presents the design of a magnetic resonance imaging (MRI) compatible needle steering system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. Our guiding vision is to design a modular needle driver that can be coupled to a generic gross positioning stage to enhance MRI-guided prostate surgery accuracy and decrease operational time. After reviewing pertaining ...
متن کاملComputerized tomography and C-Scan for measuring delamination in the drilling of composite materials using various drills
Whilst drilling is the most frequently employed operation of secondary machining for structure joining, delamination is a very serious defect during drilling of fiber-reinforced composite materials,. The evaluation of the delamination damage in the material is important but rather difficult, particularly for carbon fiber-based composites, because their colour makes visual inspection difficult. ...
متن کاملAn efficient and accurate approach for fabricating dental implant surgical guides.
The aim of this research was to develop an efficient and accurate method to fabricate a dental implant surgical guide. The surgical guide is adapted from the patient's vacuum-formed clear template with the use of a plate with three ceramic balls, a six-axis drilling machine and its fixture. The plate, with the ceramic balls used as radiographic markers, is glued to the template, and the patient...
متن کاملA Piece of Broken Metal from Intubation Stylet Retained in Tracheobronchial Tree: A Case Report
Intubation stylets are still being used in many medical centers for difficult intubations. Although very rare, it may break inside the trachea during endotracheal intubation despite routine pre-assessments by anesthesiologists and may surprisingly move deep into the tracheobronchial tree. In this case report, we describe a rare complication after stylet or guide-wire intubation in a patient in ...
متن کامل[Comparison of different stylets used for intubation with the C-MAC D-Blade® Videolaryngoscope: a randomized controlled study].
OBJECTIVE The angle of the C-MAC D-Blade® videolaryngoscope, which is used for difficult airway interventions, is not compatible with routinely used endotracheal tubes. METHODS A prospective randomized crossover study was performed comparing five intubation methods for use with standardized airways, including using different stylets or no stylet: Group HS, hockey-stick stylet; Group DS, D-bla...
متن کامل