Laser suture lysis through thick blebs using the Blumenthal lens.

نویسندگان

  • Albert S Khouri
  • Tatiana I Forofonova
  • Robert D Fechtner
چکیده

L aser suture lysis is commonly performed after trabeculectomy and is titrated to control postoperative flow through the filter to a target intraocular pressure. Originally, the flat edge of a Zeiss 4-mirror lens was used to compress the conjunctiva and Tenon capsule to view the sutures. The Hoskins lens designed for suture lysis improved the view and allowed eyelid elevation for better exposure. The Ritch suture lysis lens was designed to provide good compression and a reasonably wide field of view that helps in locating sutures. Recently, the Blumenthal lens was introduced for suture lysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucoma laser suture lysis.

AIM Suture lysis is commonly performed after trabeculectomy to improve bleb function. It is often thought to be an innocuous procedure. This is the first large study to determine the safety of the procedure and compare results with a control group. METHODS Two hundred successive trabeculectomies performed between January 1992 and October 1993 were analysed. RESULTS Ninety nine eyes underwen...

متن کامل

Sutureless revision of overhanging filtering blebs.

We describe methods and outcomes of a technique for sutureless surgical revision of symptomatic corneal overhanging filtering blebs after trabeculectomy using mitomycin in 6 eyes in 6 patients. Separation of the bleb from the corneal surface was achieved by blunt or sharp dissection, as necessary, and the overhanging portion of the bleb was excised and a bandage contact lens was inserted. Outco...

متن کامل

Lens optical quality is a direct function of lens sutural architecture.

We analyzed the structural and functional relationship between lens sutures and lens optical quality (focal length variability) by correlative scanning electron microscopy (SEM) and laser scan analysis. Twenty-two rabbit lenses (8 pigmented and 14 albino) were used in this study. Lenses were initially scanned by a low-power helium-neon laser beam that was passed either at an acute angle to a le...

متن کامل

Argon laser suture lysis with different suture materials. An experimental study.

In an in vitro study, 10/0 nylon was found to require a significantly lower laser energy density to produce suture lysis following a single shot than either 10/0 Dacron or 10/0 prolene. Nylon and Dacron monofilament sutures ruptured at reproducible energy levels without significant observable changes at subthreshold irradiation. Prolene, however, was observed to stretch at energy levels below t...

متن کامل

The etiology of transient endothelial changes in the human cornea.

To investigate the etiology of contact lens-induced transient endothelial changes (blebs) in the human cornea, the effects of five different stimuli on corneal thickness and the appearance of the corneal endothelium were assessed. The stimuli included: (1) a silicone contact lens; (2) a silicone contact lens in combination with anoxia; (3) anoxia alone; (4) a thick hydroxyethyl methacrylate (HE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 124 4  شماره 

صفحات  -

تاریخ انتشار 2006