Cataract surgery with implantation of a mechanically and reversibly adjustable intraocular lens: *Acri.Tec AR-1 posterior chamber intraocular lens.

نویسندگان

  • Claus E Jahn
  • Dörte C Schöpfer
چکیده

I f it were possible to adjust the refraction of a pseudophakic eye by means of an adjustable posterior chamber intraocular lens (PC/IOL), subjective comfort or visual function would be improved. This is especially true in children. Several approaches to create an adjustable intraocular lens (IOL) are currently under study. This field is still in an early stage of its evolution. The *Acri.Tec AR-1 PC/IOL (*Acri.Tec, Hennigsdorf, Germany) is a mechanically and reversibly adjustable PC/IOL, which has been implanted and adjusted in adult human eyes. So far the results after short-term follow-up of the initial cohort suggest that the use of this PC/IOL would be safe. Through continued observation of the eyes from this cohort we have tried to determine the long-term safety of this PC/IOL, behavior of the PC/IOL after Nd:YAG laser capsulotomy, and refractive stability of the eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation

The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...

متن کامل

The Effect of Phacoemulsification with Posterior Chamber Intraocular Lens Implantation on Intraocular Pressure and Anterior Chamber Depth

Purpose: To evaluate intraocular pressure (IOP) and anterior chamber depth (ACD) change after phacoemulsification with posterior chamber intraocular lens implantation Methods: In this quasi-experimental study, 84 patients with senile cataract were included. All patients had normal IOP. Patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease or...

متن کامل

Comparison of Patient's Satisfaction Level after Different Types of Posterior Chamber Intraocular Lens Implantation

Objective. To compare patient's satisfaction level in performing routine activities during daylight and night vision after implantation with rigid, foldable, or rollable posterior chamber intraocular lens implants in uneventful cataract surgery. Design. Retrospective, cross-sectional. Place and Duration of Study. PNS SHIFA Hospital, Karachi, from Nov. 2009 to Nov. 2010. Methodology. 91 cataract...

متن کامل

Management of bipseudophakia with implantation of an iris claw lens.

We discuss a case of bipseudophakia with secondary dislocation of a posterior chamber intraocular lens (IOL) into the anterior chamber that was managed by explantation of the anterior and posterior chamber IOLs and implantation of an iris claw IOL.

متن کامل

Broken intraocular lens during cataract surgery.

A case of planned routine extracapsular cataract extraction is described where surgery was complicated peroperatively by fracture of the posterior chamber lens implant. The technique of lens implantation is discussed.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 125 7  شماره 

صفحات  -

تاریخ انتشار 2007