Arterial oxygen saturation profiles in healthy preterm infants.
نویسندگان
چکیده
AIM To construct a reference range of SpO2 values in healthy preterm infants using a simple data logging device. METHODS Thirty three healthy preterm infants were monitored for a continuous period of 4 hours at rest using an Ohmeda Biox 3700 E Pulse Oximeter and an electronic data logger (Rustrack Ranger). Stored data were downloaded and saved as individual files on a personal computer. RESULTS The study group median and 5th and 95th percentiles were used to construct a cumulative frequency curve of time against SpO2 value, representing the normal reference range of SpO2 profiles in healthy preterm infants. CONCLUSION Comparison of an infant's SpO2 profile against this curve may be more helpful in guiding supplemental oxygen treatment in that individual than a figure for a mean SPO2 and its standard deviation.
منابع مشابه
Effect of Different Positions on Arterial Oxygen Saturation during Enteral Feeding of Preterm Infants Admitted to Neonatal Intensive Care Units
Background: This study aimed to determine the effects of various positions on the arterial oxygen saturation during enteral feeding of preterm infants admitted to Neonatal Intensive Care Units (NICUs). It is assumed that different body positions influence arterial oxygen saturation during enteral feeding.Methods: This crossover clinical trial included 88 infants. The inclusion criteria we...
متن کاملThe Effect of Plastic Cover on Regulation of Vital Signs in Preterm Infants: A Randomized Cross-over Clinical Trial
Background: Considering the susceptibility of preterm infants to disturbances of vital signs, this study was conducted to investigate the effects of using plastic covers on regulation of vital signs in preterm neonates.Methods: This randomized, cross-over, clinical trial was carried out on 80 preterm infants admitted to neonatal intensive care unit (NICU) of Taleghani Hospital, Tabriz, Iran. Th...
متن کاملPulse oximetry in preterm infants.
One hundred and twenty five measurements of arterial oxygen saturation (Stcao2) obtained with a transcutaneous pulse oximeter were compared with direct arterial oxygen tension (Pao2) in 13 preterm infants with predominantly fetal haemoglobin. Stcao2 of 86-92% corresponded to Pao2 of 5-13 kPa. Stcao2 above 92%, however, was sometimes associated with Pao2 above 13 kPa.
متن کاملEffect of the Artificial Night with Facilitated Tucking and Artificial Night Alone on the Physiological Indices of Premature Infants
Background: Preterm birth and admission to neonatal intensive care unit as stressors can cause physiologicalinstability that may lead to prolong hospitalization and mortality. This study aimed to determine the effect of artificialnights and facilitated tucking on the physiological indices of premature infants.Methods: This randomized clinical trial was conducted on 60 preterm ...
متن کاملRespiratory instability of term and near-term healthy newborn infants in car safety seats.
OBJECTIVE Premature infants who are discharged from intensive care nurseries are known to be at increased risk for apnea, bradycardia, and oxygen desaturation while in the upright position. These small infants also do not fit securely in standard infant car seats. Because of these problems, the American Academy of Pediatrics recommends a period of observation in a car seat for all infants who a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood. Fetal and neonatal edition
دوره 79 1 شماره
صفحات -
تاریخ انتشار 1998